SATEL CA-10 23
[0][1] [#] - detector type for the seventh zone (LEDs 9-12 = 0111)
[0][1] [#] - detector type for the eighth zone (LEDs 9-12 = 1000)
[0][1] [#] - detector type for the ninth zone (LEDs 9-12 = 1001)
[0][1] [#] - detector type for the tenth zone (LEDs 9-12 = 1010)
[0][1] [#] - detector type for the eleventh zone (LEDs 9-12 = 1011)
[0][1] [#] - detector type for the twelfth zone (LEDs 9-12 = 1100)
[0][0] [#] - no detector on zone 13 (LEDs 9-12 = 1101)
[0][0] [#] - no detector on zone 14 (LEDs 9-12 = 1110)
[0][0] [#] - no detector on zone 15 (LEDs 9-12 = 1111)
[0][0] [#] - no detector on zone 16 (LEDs 9-12 = 0000)
In LCD keypads, two ways of programming the zone type are possible: by pressing the keys
from 0 to 5 (0 - no detector; 1 - NC; 2 - NO; 3 - 2EOL; 4 - 2EOL/NC; 5 - 2EOL/NO) or by
means of the keys and , which make possible scrolling through the zone type lists. The
keys and enable the subsequent zones to be scrolled. Having programmed the zone
type for all zones, confirm them by pressing the key [#], which is equivalent to quitting the
function. Suspension of the programming is possible by pressing the [
*
] key.
FS26 - programming zone reaction type (DEC)
The control panel reaction to a zone violation depends on the function assigned to the given
zone (e.g., the reaction will be different in the case of 24 H FIRE zone violation, and in the
case of ARMING zone violation).
The programming consists in entering an appropriate two-digit number for each zone to
determine its reaction type. Each of the CA-10 zones can be programmed for:
00 - ENTRY/EXIT
01 - DELAY
02 - INTERIOR DELAY
03 - INSTANT
04 - DAY/NIGHT
05 - COUNTING L1
06 - COUNTING L2
07 - COUNTING L3
08 - 24H AUDIBLE
09 - 24H AUXILIARY
10 - 24H SILENT
11 - 24H FIRE
12 - ARMING
13 - SILENT ARMING
14 - DISARMING
15 - NO ALARM ACTION
16 - ARMING/DISARMING
17 - DELAY AUDIBLE
18 - AUTOMATIC BYPASS ARMING
19 - PERIMETER
20 - ENTRY/EXIT-FINAL
Both in the LED and LCD keypads, the programming consists in entering for each zone an
appropriate two-digit number, which determines the zone reaction type. In the LCD keypads,
setting the zone reaction type is also possible by means of the keys and , which scroll
the reaction type list. The keys and enable the next zones to be scrolled.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 Installation Guide - English - 43 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info