699577
24
Zoom out
Zoom in
Previous page
1/60
Next page
22 Programming SATEL
EXAMPLE:
LEDs: 1,3,6,8 are on, which gives value = 165:
State of the LEDs from 1 to 8 :  
VALUE
: 128+32 + 4+1 = 165
REACTION TIME
(ms):
PROGRAMMED VALUE
(165)
X
16
ms
=
2640
ms
In the LCD keypad, the time is programmed directly in milliseconds from 16 to 4080 (the
value is automatically rounded up to the multiple of the number 16).
By default, all the zones have the same reaction time (480 ms). In most cases, no change of
the time setting will be required.
The function is intended for advanced installers. It allows the zone sensitivity to be selected
where special detectors are used (for example, mechanical detectors of broken glass, or low
hysteresis detectors, not fitted with monovibrator at the output).
Note: The minimum sensitivity of the keypad zones and expander zones is 64 ms
(4 x 16 ms). The actual sensitivity values of these zones can amount to n x 64 ms
(n=1,2,3,...). This results from the way the keypad is handled by the control panel –
the status of these zones is read out at intervals of exactly 64 ms.
FS25 - programming zone type (DEC)
Selection of the zone type depends on the type of detector, as well as configuration of its
connection to the control panel. The following types of detectors and configuration are
possible: NC, NO, EOL, 2EOL/NC, 2EOL/NO. Determination of the type of detector and
configuration is necessary, since interpretation of information received by the control panel
will depend on it. For example, an open zone can mean correct state of the NO detector or
violation of the NC (or EOL) detector, as well as tamper violation in the case of 2EOL
configuration.
Programming in the LED keypad consists in entering the suitable two-digit number (to
determine the detector type and configuration) for the particular zones. Having confirmed the
detector type and configuration for one zone, the control panel proceeds to programming the
next type of zone, until particular detector types and configuration are assigned to all 16
zones. The following numbers are correct:
00 - no detector (for not used zones)
01 - NC detector (normally closed)
02 - NO detector (normally open)
03 - EOL detector (End Of Line Resistors - default value)
04 - 2EOL/NC detector (Double End Of Line Resistors – NC detector)
05 - 2EOL/NO detector (Double End Of Line Resistors – NO detector)
During the programming, the control panel will display the current parameter setting (in
binary form) on the LEDs 1 to 8. The LEDs 9 to 12 indicate the zone for which the detector
type is being programmed. (for zones 1-15 binary – see: Table of character coding for LED
keypads; for zone 16 LEDs 9-12 are off)
EXAMPLE:
programming the EOL type zones 1 do 6, NC type zones 7 to 8, the other zones (13 to 16)
not used
[2][5] [#] - call the function
[0][3] [#] - detector type for the first zone (LEDs 9-12 = 0001)
[0][3] [#] - detector type for the second zone (LEDs 9-12 = 0010)
[0][3] [#] - detector type for the third zone (LEDs 9-12 = 0011)
[0][3] [#] - detector type for the fourth zone (LEDs 9-12 = 0100)
[0][3] [#] - detector type for the fifth zone (LEDs 9-12 = 0101)
[0][3] [#] - detector type for the sixth zone (LEDs 9-12 = 0110)
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 User Manual - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 Installation Guide - English - 43 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info