Page 23FT-950 OPERATING MANUAL
FRONT PANEL CONTROLS & SWITCHES
[
R.FLT
]
(
R
OOFING
F
ILTER
)
Switch
This button selects the bandwidth of the receiver first
IF Roofing Filter. Available selections are 3 kHz, 6
kHz, 15 kHz, or Auto. The selected bandwidth appears
in the FLT column of the Block Diagram Display on
the display.
ADVICE:
Because the roofing filter is in the first IF, the protec-
tion it provides against interference is quite significant.
When set to AUTO, SSB bandwidth is 6 kHz, CW is 3
kHz, FM and RTTY are 15 kHz. On a crowded SSB
band, however, you may wish to select the 3 kHz filter,
for the maximum possible interference rejection.
[
NB
]
Switch
This button turns the IF Noise Blanker on and off.
Press this button momentarily to reduce short-duration
pulse noise; the “ ” icon will appear in the display.
Press and hold this button in for one second to reduce
longer-duration man-made pulse noises; the “
icon will blink for three seconds, then will appear con-
tinuously in the display.
Press this button again to disable the noise blanker;
the “ ” icon will disappear.
[
AF GAIN
] [
RF GAIN
]
Knobs
[
AF GAIN
]
Knob
The inner
[
AF GAIN
]
knob sets the receivers audio
volume level. Typically, you will operate with this con-
trol set between the 9 o’clock and 10 o’clock posi-
tions.
[
RF GAIN
]
Knob
The outer
[
RF GAIN
]
knob is the receivers RF gain
control, which adjusts the gain of the receivers RF
and IF amplifier stages. This control is normally left in
the fully clockwise position.
[
RX CLAR
]
Switch
Pressing this button activates the RX Clarifier. This
will allow you to temporarily adjust the receiving fre-
quency up to ±9.999 kHz with the
[
CLAR/VFO-B
]
knob. Press this button once more to return the receiver
to the original frequency; the Clarifier offset will be
remembered, in case you want to use it again. To can-
cel the Clarifier offset, press the
[
CLEAR
]
button.
[
TX CLAR
]
Switch
Pressing this button activates the TX Clarifier, to al-
low offsetting the transmit frequency temporarily. Press
this button once more to return the transmitter to the
original frequency; the Clarifier offset will be remem-
bered, though, in case you want to use it again. To can-
cel the Clarifier offset, press the
[
CLEAR
]
button.
[
CLEAR
]
Switch
Pressing this button clears out any frequency offset you
have programmed into the Clarifier register (thereby
setting the offset to “Zero”).
[(
VFO-B
)
RX
]
Indicator/Switch
This button switches the receiving frequency to VFO-
B, the green LED imbedded within the button will light
up. Pressing this button again will return the receiving
frequency to VFO-A, and the imbedded green LED
will turn off.
[(
VFO-B
)
TX
]
Indicator/Switch
This button transfers control of the transmit frequency/
mode to VFO-B, and the red LED in the button will
light up. Pressing this button again will transfer fre-
quency/mode control back to the VFO-A side, and the
red LED imbedded within this button will turn off.
[
BAND
]
Switch
Pressing this button allows you to select the operating
band (Amateur bands) by turning the
[
CLAR/VFO-
B
]
knob.
[
GRP
]
Switch
Pressing this button allows you to select the memory
group by turning the
[
CLAR/VFO-B
]
knob.
[
MHz
]
Switch
Pressing this button allows you to tune the VFO fre-
quency down or up in 1 MHz increments, using the
[
CLAR/VFO-B
]
knob.
[
CLAR/VFO-B
]
Knob
This knob usually tunes the Clarifier offset frequency
up to ±9.999 kHz. Additionally, it is used to adjust the
functions selected with five buttons located around the
knob.
[
MCH
]
Switch
Pressing this button allows you to select the memory
channel using the
[
CLAR/VFO-B
]
knob.
EFFECT
Rotate the
[
CLAR/VFO-B
]
knob to adjust
the VFO-B frequency, in the same step as
the Main Tuning Dial knob. The Frequency
Display will be changed to show the VFO-
B frequency.
Rotate the
[
CLAR/VFO-B
]
knob to change
the amateur band selection.
Rotate the
[
CLAR/VFO-B
]
knob to select
the memory group.
Rotate the
[
CLAR/VFO-B
]
knob to tune the
VFO frequency in 1 MHz step.
Rotate the
[
CLAR/VFO-B
]
knob to select
the memory channel.
FUNCTION
SWITCH
[(
VFO-B
)
RX
]
[
BAND
]
[
GRP
]
[
MHz
]
[
MCH
]
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-950 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-950 in the language / languages: English as an attachment in your email.

The manual is 6,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info