815507
18
Zoom out
Zoom in
Previous page
1/56
Next page
1818 3-90-30007498Vermont Castings • Radiance RADVT Installation Manual_R32 • 10/23
DivertRoofRun-o󰀨
HHT recommends, where excessive water run-o󰀨 is possible,
use of one of the two options shown in Figure 3.10 to prevent
water running off the roof and onto/into the horizontal
termination cap.
4. Using appropriate length of pipe section(s) attach to
stove by twisting collar.
5. Measure the horizontal length requirement including a 2”
(51 mm) overlap, i.e. from the elbow to the outside wall
face plus 2” (51 mm) (or the distance required if installing
a second 90° elbow), Figure 3.13.
NOTE: Always install vertical side wall horizontal venting
with a 1/4” rise for every 12” of run.
2. Secure restop to the inside frame, center in the 10" x 10"
vent opening.
3. Place stove into position. Measure the vertical height (X)
required from the base of the ue collars to the center of
the wall opening, Figure 3.12
Vertical Side Wall Installation:
NOTE: Refer to Figures 2.8 thru 2.10 for restrictor plate
adjustments for vertical vent runs.
1. Locate vent opening on the wall. It may be necessary
to rst position the stove and measure to obtain hole
location. Depending on whether the wall is combustible
or noncombustible, cut opening to size, Figure
3.11 (For combustible walls rst frame in opening.)
Combustible Walls: Cut a 10" x 10" (254 x 254 mm) hole
through the exterior wall and frame as shown, Figure 30.
Noncombustible Walls: Hole opening must be 7" (178
mm) in diameter.
Install gutter
Install L-shaped
diverter
Figure 3.10 - Locate Vent Opening on Wall
VentOpeningforCombustibleWalls
VO584-100
Vent Opening
2/99 djt
Stove Hearth Framing Detail
OpeningforNoncombustibleWall
7"
(178 mm)
Stove Hearth
10"
(254 mm)
10"
(254 mm)
Figure 3.11 - Locate Vent Opening on Wall
X
Figure 3.12 - Vertical Height Requirements
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info