815507
20
Zoom out
Zoom in
Previous page
1/56
Next page
2020 3-90-30007498Vermont Castings • Radiance RADVT Installation Manual_R32 • 10/23
VerticalThrough-The-RoofApplication/Installation:
Note: Refer to Figures 2.8 thru 2.10 for restrictor plate
adjustments for vertical vent runs.
This gas stove has been approved for:
Vertical installations up to 40 feet (12 m) in height. Up to
a 10 feet (3 m) horizontal vent run can be installed within
the vent system using a maximum of two 90° elbows,
Figure 3.17.
Up to two 45° elbows may be used within the horizontal
run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by 18"
(450 mm).
Example: Maximum horizontal length:
No elbows = 10' (3 m)
1 x 45° elbow = 8.5' (2.6 m)
2 x 45° elbows = 7' (2.1 m)
A minimum of an 8 feet (2.5 m) vertical rise is required,
Figure 3.17.
Two sets of 45° elbow o󰀨sets may be used within the
vertical sections. From 0 to a maximum of 8 feet (2.5 m)
of vent pipe can be used between elbows, Figure 3.17.
SLP-HVS supports o󰀨sets. This application will require
that you rst determine the roof pitch and use the
appropriate starter kit. (Refer to Venting Components
list.)
The maximum angular variation allowed in the system is
270°, Figure 3.18
For the minimum height of the vent above the highest
point of penetration through the roof, Figure 3.18.
ST653
install snorkel
04/19 ts
RADIANCE
Waterproof Seal
Around Pipe
Firestop
Window Well
Drain
12"
Clearance
Snorkel
Termination Cap
Wall Screws
and Anchors
Gravel
Figure 3.16 - Snorkel kit installation.
Figure 3.17 - Typical Vertical Venting Conguration
ST933
Selkirk vertical venting
6/07
Ceiling Support Collar
Ceiling
Support
Plate
Trim Plate
Firestop
Spacer
O󰀨set
Support Collar
Flashing
Storm Collar
Vertical Termination
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info