810451
38
Zoom out
Zoom in
Previous page
1/44
Next page
GB 38
1Support
2Automatic flue gas damper with handle
1Heat exchanger pipe
2Handle of flue gas damper
Subsequently, the heat exchanger pipes and the middle channel, as well as
the outer surfaces of the heat exchanger and the flue gas manifold must
be cleaned with the provided brush or a hand brush. Then the deposits fall
automatically into the combustion chamber and they can be removed with
standard aids (ash shovel, ash broom or an ash vacuum).
After cleaning, assembly is executed in the reverse sequence. First, hook in
the thermal flue gas damper (introduce diagonally from below and place in
on the supports). Then insert the flame deflector plate so that the flue gas
gap is on the disc side.
5.2 CLEANING THE DOUBLE GLAZING
If the fireplace insert is equipped with double glazing, the owner must
only clean the double glazing on the combustion chamber side and the
installation room side, in accordance with the information in the operating
instructions. If the inner panes in the hollow space are contaminated, then
cleaning must only be executed by the customer service organisation or a
trained specialised company. In operation, a slight bright shimmer may be
seen between the glass panes. However these deposits do not constitute
grounds for complaint.
5.3 BYPASS DAMPER VARIA 1V/1Vh H2O/XL/XXL
To prevent the escape of heating gases, a bypass damper see FIG.9) is
installed parallel to the heat exchanger in the front area. The bearing points
are arranged directly next to the water connections and must be reachable
for maintenance and service tasks. The bearing arrangement is on the left
side of the device and can be reached from the combustion chamber.
I. II.
11
11
2
Fig. 8a
2
1
Fig. 8b
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Mini H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Mini H2O in the language / languages: English as an attachment in your email.

The manual is 4.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Mini H2O

Spartherm Mini H2O User Manual - German - 44 pages

Spartherm Mini H2O User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info