810451
35
Zoom out
Zoom in
Previous page
1/44
Next page
GB
GB 35
Shifting the stop to 100 mm reduced opening height
This setting can be used if the flue gas system is not suitable for open
operation when putting more wood on the fire. By reducing the opening
height of the door, the air mass flow rate is reduced.
1. Close the elevating door, so that the fastening screws can be reached.
2. Unscrew the M5x10 threaded screws an both sides of the device with a
4 mm Allen wrench (ball head).
3. Pull off the door stop in the direction of the red arrow. It is possible that
it may have seized slightly and must be "levered off" from below with a
slot-head screwdriver.
4. Insert the door stop with the long bracket toward the front of the device.
Ensure that the door stops are not swapped out.
3. INITIAL COMMISSIONING
Heat generation systems must only be produced and installed by specialised
companies. The initial commissioning must only be executed by an expert
employee of the installation company. A certificate confirming proper instal-
lation and proper adjustment / function of all control components and safety
components must be given to the owner / operator of the system.
The initial commissioning must only be executed after all neces-
sary components are connected and all necessary safety devices
are integrated and functional. Before the stove / fireplace insert is
placed in service, it must be filled and ventilated on the heating side
(heating network) and water side (thermal discharge safety device;
safety heat exchanger). After the filling process, check all hydraulic
connections for leaks. Operation without a water-side connection
results in irreparable damage and invalidates any warranty claims!
The first four firings must each be executed with max. 2.0 kg/hour of
dry and thin wood (max. circumference 25 cm). Through this measure
the fireplace insert, the chamotte and the vermiculite are slowly tempered
and thus the moisture that may be present due to storage, transport, etc. is
slowly dissipated. If this does not occur, contamination of the area between
the glass panes, as well as tearing of the chamotte are possible.
Attention: Underneath the fireplace insert up to 0.5 litres of concentrate
can escape! This is not a leak!
The owner must be instructed in detail concerning the operation, function
and maintenance of the overall system, including all supplemental compo-
nents. In addition, the measures for maintaining safe operation of the sys-
tem must be communicated to the owner. The executed instruction must
be documented in the commissioning protocol! The installation and
operating instructions must always be kept in good condition in the vicinity
of the H2O fireplace insert where they can be easily accessed. Additional
Fig. 7b Fig. 7b
*The door hood has been removed only for the purpose of better documentation.
Left device side Right device side
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Mini H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Mini H2O in the language / languages: English as an attachment in your email.

The manual is 4.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Mini H2O

Spartherm Mini H2O User Manual - German - 44 pages

Spartherm Mini H2O User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info