Additional Functions and Connections
17
Connecting external device
Terminal Label Function
90 V
10 24 V 24V output, fused with 1A
max. 20W
Rectified, not stabilised transformer voltage, fluctuating
between 22V and 27V at full load.
Connecting Drives
Terminal Label Function
5 + 6 M1 single-wing gate: no function assigned
double-wing gate: connection for motor-1
The motor must be mounted on the wing
that opens as the second wing, or that is
equipped with a stop bar at the outside.
Terminal 5: Motor cable, brown
Terminal 6: Motor cable, blue
7 + 8 M2 single-wing gate: connection for motor
double-wing gate: connection for motor-2
The motor must be mounted on the wing
that opens as the first wing, or that is not
equipped with a stop bar at the outside.
Terminal 7 Motor cable, brown
Terminal 8: Motor cable, blue
Connecting to Power Supply (230V)
Terminal Label Function
1 L Power conductor 230V AC
2 N Neutral conductor
3 + 4 PE Earth conductor
The connection to the power supply must be carried out by a qualified
electrician.
Connection of transformer
Terminal Label Function
19 + 21 230V AC Power supply (primary winding), brown
23 + 24 24V AC 24V output (secondary winding), power
supply line to control unit, mauve
Motor circuit board
Terminal Function / cable colour
1 24V supply line from control unit, blue
2 Limit switch gate “CLOSE”, blue
3 Limit switch gate “CLOSE”, blue
4 Motor, blue
5 24V supply line from control unit, brown
6 Limit switch gate “OPEN”, yellow
7 Limit switch gate “OPEN”, yellow
8 Motor, black