Accessories
19
5. External aerial
• If the built-in aerial is not sufficient for the proper operation of the gate,
you have the option to connect an external aerial to the system.
• Ensure that the aerial cable is laid in such a way that there is no physical
impact to the radio transmitter. Install tension protection, if necessary.
• Consult the operator/owner of the system in order to find a suitable loca-
tion for the external aerial.
• Connect external aerial to the respective adapter.
6. Main switch
Electric lock 24V
Installation:
• Reset the control system.
• After completion of the installation adjust end position gate “CLOSE”.
• Mount the lock horizontally, as it might otherwise be jammed when the
gate is operated.
• Distance between lock and closing plate: min. 4 mm, max. 6 mm.
Connecting 24V electric lock
This diagram is only applicable to 24V electric locks. If you wish
to install a 12V electric lock, you must first contact the
manufacturer.