Installation
22081814H 99
Transition Speed
speed: 00 kn
Transition
INSTALLATION
The transition speed is the speed where the AP300 will automatically
change the steering parameter set from the HI speed to LO speed
parameters, or vice versa.
The default setting of transition speed is zero, which requires that
steering parameter selection be done manually. If a GPS, Loran, or
external speed log input (from Dataline or other instrument systems) is
connected, it is recommended to set the transition speed to a value
greater than 0, to enable the automatic speed selection feature in the
AP300X.
It is recommended that you set the transition speed to a speed that
represents the speed where the hull begins to plane, or where you
would manually change the parameters from HI to LO.
The speed used for the automatic transition is obtained as follows:
1. Data from the source set in the interface setup for the S / D
channel. If this is a valid source of VHW (speed through the water)
data, then this data is used for determination of when to change
parameter sets.
2. If VHW data is not available from the S/D channel or if the S/D
channel is not configured, the AP300X system will use the speed
data obtained from the VTG (speed over ground) sentence received
from the currently selected POS source.
If no speed data is available on either the S/D channel (VHW) or the
POS source (VTG), manual speed selection is required. The AP300 will
always default to the HI speed steering parameters when the system is
first turned on, and with speed data failure.
If manual speed selection occurs (the user manually selects HI or LO
parameters), the manual parameter set will remain in effect until the
AUTO mode is reselected.
Rotate the course dial clockwise until the transition speed is set to the
desired value in knots.
Proceed to next menu item by pressing STBD [>] button.
101


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad Robertson AP300X Marine Autopilot at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad Robertson AP300X Marine Autopilot in the language / languages: English as an attachment in your email.

The manual is 4,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info