50953
8
Zoom out
Zoom in
Previous page
1/20
Next page
Manual SA 250
pag. 6
PCG/C SA 250 Manual 27-03-07
Hi-Lo weighing continued
Setting the weight limits
HI
1. Press key . The symbol and the red LED at HI show up.
The present value of the upper limit is shown. The last figure is flashing
and may be changed now with the cursor key .
With key the next figure may be turned on and so on.
LO
2. Press key again. The yellow LED at Lo will light up.
The present value of the upper limit is shown.
Continue procedure as with the entering of the upper limit value.
3. By pressing key again, display reading will return to the weighing
mode.
A check of the present weight values only may be done by simply pressing
key three times.
This Lock-up function is permanently switched off at legal stamped scales.
The weight value of a weighing may be locked up temporarily.
This may be done in two different way’s: (setting in CAL menu):
F1 - The weight value will be locked up as soon as the reading comes to a
exact standstill, until the scale display returns to zero and comes to
a standstill at zero.
F2 - The weight value will be locked up as soon as a standstill within 1, 2 or 3
scale divisions is determined. However if the real weight value changes
for at least 1,2 or 3 scale divisions, the lock up will be set free .
On the condition that the Hold function has been selected in the Calibration
Menu, the function may be switched on and off by pressing key .
The display shows in the left corner above, which of the hold functions is in
operation with the symbols: F1 or F2.
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
NET
NET
Hold mode (in weighing mode only, and the function has to be selected in CAL mode)
F 1
NET
F 2
NET
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satex . . SA 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satex . . SA 250 in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satex . . SA 250

Satex . . SA 250 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info