50953
20
Zoom out
Zoom in
Previous page
1/20
Next page
pag. 18
Manual SA 250
PCG/C SA 250 Manual 27-03-07
Lod . . . stays on display. At switching on the weight signal is too low.
Check the correct position of the weigh platform and possible damage of the
connecting cable and connector.
The loadcell could be damaged.
Execute a new one point adjustment procedure until the point 2 (zero setting).
The scale has been switched on, but zero setting is not possible since the
weight signal is higher or lower as 10% of the scale capacity.
Remove the load on the weigh platform. Check cable and connector.
Execute a new one point adjustment procedure until point 2 (zero setting).
The scale refuses zero setting.
The weight signal is outside the zero setting range(+ and - 2% scale capacity).
Tare function will operate correctly. Switch the scale off and on again so a
new zero (+ and - 10% scale capacity) may be settled.
Reading is gross
negative. Set zero and set tare not possible.
The scale has been switched on with a load on the platform and has set zero
with this load. Thereafter, the load has been removed and now the reading is
gross negative. Switch the scale off and on again with an empty platform.
The load on the platform is higher as the maximum scale capacity: overload.
Remove the load from the weigh platform. Check cable and connector.
The loadcell could be damaged.
The weight signal is far too negative. Check the correct position of the weigh
platform and clean the interior of the platform. Check for damage of the cable
and connector. The loadcell could be damaged.
Execute a new adjustment procedure.
Power supply excitation is too low, battery is empty.
Recharge the battery.
The Hi-Lo function cannot be selected with key F
.
- No weight values has been entered in the Hi-Lo mode.
Enter upper and down limit weight values with the key Hi-Lo.
- The Hi-Lo function is disabled in the USER mode.
The Lock up function cannot be selected with key F
.
- The Lock up function is disabled in the Calibration mode.
No data transmission or printing follows after operating the printer key.
- The transmission function is disabled in the USER mode
- Scale reading is at zero
- Scale reading has not been on zero with standstill after the last transmission.
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
Malfunctions and error codes
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satex . . SA 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satex . . SA 250 in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satex . . SA 250

Satex . . SA 250 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info