699578
15
Zoom out
Zoom in
Previous page
1/36
Next page
CA-6 SATEL 13
It is recommended that the cable be first connected to the control panel, and then to
the computer.
4. The DIALERLED is on during telephone messaging by the panel, and blinks during
pulse dialing of the telephone number.
BOARD TERMINALS:
AC – module power supply inputs (18 V AC ± 10%)
Z1 to Z6 – zones
OUT1 to OUT3 – programmable outputs (current-carrying capacity 2.2 A)
OUT4, OUT5 – programmable outputs (current-carrying capacity 50 mA)
DATA, CLK – keypad terminals
CTL – control input
+KPD – keypad power supply output (current-carrying capacity 1.5 A)
+12V – power supply outputs
COM – common ground
protective terminal – ground (connect to protective circuit only)
TIP, RING – terminals of outside telephone line
T-1, R-1 – terminals of extension telephone line (telephone set)
The AC terminals are intended for providing the alternating supply voltage from the mains
transformer. The control panel power supply unit is suitable for the 18 V ± 10% AC input
voltage. The control panel is fitted with an advanced pulse-type power supply of high energy
efficiency and operational reliability, however, its correct functioning requires that the input
voltage at the maximum load of the transformer by the control panel does not drop below
16 V AC.
The CA-6 main board enables a grounding circuit to be connected. The ground lead terminal
is designated by the symbol.
The control panel power supply (current capacity 1.2 A) is fitted with:
voltage control system (the stabilized voltage of the control panel power supply is
+13.6 V to +13.8 V and is factory set),
battery status monitoring system with optional disconnection of the battery if
discharged during testing the processor reduces the power supply and the loads are
powered from the battery. The testing takes place every 4 minutes and lasts for less
than twenty seconds. If the battery voltage drops down to 9.5 V, the control panel will
cut off the battery in order to prevent it from a complete discharge and damage.
Attention should be paid so as not to cause overloading of the control panel power supply in
the alarm system. It is advisable to make a load balance for the power supply. The total
current inputs for the consumers (detectors, keypads) and the battery charging current may
not exceed the power supply capacity. In case of a higher electric power
demand, an additional power supply can be used for some of the
security system consumers (e.g. APS-15, APS-30 manufactured by
SATEL). The Table 1 (at the end of this manual) shows an example of
estimated balance of current consumption by the system, and an
example of battery selection.
Each of the high-current outputs OUT1 – OUT3 and +KPD is fitted with
electronic short-circuit and overload protection devices.
Two wires (red and black) are intended for connecting the battery, the
red one is connected to the battery „+” terminal, the black one to the „-”
terminal. The battery cables lugs should not be cut off.
The RS232 TTL interface is designed for programming the alarm
system parameters from a computer. The panel sends and receives
PRESS IN
BEND ASIDE
BEND ASIDE
Fig. 3.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-6 in the language / languages: English as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-6

Satel CA-6 Additional guide - English - 40 pages

Satel CA-6 Quick start guide - English - 8 pages

Satel CA-6 Additional guide - German - 19 pages

Satel CA-6 User Manual - German - 19 pages

Satel CA-6 Installation Guide - German - 80 pages

Satel CA-6 User Manual - German - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info