current running period of the timer is shown.
While the timekeeper continues counting in OFF mode, the respective timer LED is glowing permanent-
ly. This shows that the value on the 7-segment display relates to the timer, whereas it cannot be directly
altered at that stage. To this end, the control must first be reactivated using the ON/OFF sensor.
A timer LED permanently glowing during active mode shows that the timer of the respective cooking
zone has been programmed and is counting down, whereas the time is not being indicated on the
7-segment display.
Provided there is no further adjustment made within 10 seconds after activation of the timer (the
display keeps indicating “00”), the display as well as the allocation of the PLUS/MINUS sensors change
back automatically into the power level setting mode. If no cooking zone is activated, the control chan-
ges immediately into the OFF mode after the 10-second period.
Setting the timer value (running period)
Having activated a timer, the belonging LED is blinking as described. The requested countdown period
of the timer (running period) can then be set using the PLUS/MINUS sensors.
Starting with the PLUS sensor, the first value indicated is skipped to “01” and is increasing by single
steps to a maximum of “99” (= final maximum power level setting) with every further activation.
Starting with the MINUS sensor, the indicated value is skipped to “30” and is decreasing by single
steps down to “01” (initial minimum power level setting; when reached, a signal tone is heard) with
every further touch of the sensor. In order to attain the value “00”, the MINUS sensor must be released
and activated anew. Further activation of the MINUS sensor will not alter the “00” indication (= final
minimum power level setting).
When activating the sensors permanently, the setting speed is automatically accelerated, i. e., the time
required from one step to another is reducing as long as the sensor is being activated.
When the PLUS or MINUS sensors are not activated within 10 seconds subject to cooking zone related
programming, the indicator and the allocation of the PLUS/MINUS sensors automatically change back
to the power level setting. When using a timer as a timekeeper, the indicator and the sensor allocation
do not change back to the power level setting, as it must not be activated for the duration of that
period.
Timer settings take priority over the operating time limitation subject to high power level settings (refer
to table on “operating time limitation”).
When nothing but a timekeeper has been programmed, the control maintains the wait mode first (with
no other cooking zones being activated). Provided there is no input of new values, the control proceeds
as described and changes into OFF mode.
Timer countdown
For the last 10 seconds of the timer countdown the indicator always adapts itself to the timer and
counts down the seconds.
When the countdown of the time is completed, there is an audible signal and the respective cooking
zone is deactivated. Thereafter, the indications “00” and “H” (if residual heat is prevailing) appear
alternately, while the belonging timer LED is blinking in addition.
After a maximum of 2 minutes or by activating any sensor, the signalling is stopped.
Interrupting the timer / Altering the timer value (running period)
The setting value of a timer can be altered at any time after its activation or in timekeeping mode using
the PLUS or MINUS sensor.
A timer can be deactivated by adjusting the setting to “00” using the MINUS sensor. Also, it can be
immediately reset to “00” by activating both the PLUS and the MINUS sensor simultaneously.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rommelsbacher EBC3477TC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rommelsbacher EBC3477TC in the language / languages: English, German as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info