14. Measure the CO
2
percentage at full load, in the flue
gas discharge pipe, directly above the casing. The
measured value must be compared with the value
indicated in the table. If the measured value deviates
from the value mentioned in the table, it can be
adjusted by turning the V-controller (see figure 21 or
22) on the gas multi-block.
Please note:
Only turn the V-controller at full load and only turn
the N-controller at part load. Turning the controller
slightly may have a large influence on the load
and the CO
2
percentage.
The CO
2
percentage increases by turning this control
ler clockwise. If, after turning the V-controller, the
value corresponds with the table value, or falls at
least within the specified tolerance, check the
following points:
a) the combustion quality by looking through the
sight holes in the end sections.
Check that - the flames do not blow off,
- the burner surface is not red-hot.
b) the differential pressure between the measuring
points pF and pG (see fig. 19 for 7 and 9 sections
and fig. 20 for 11 to 19 sections). See table on the
boiler for value.
If, when checking the points mentioned under a) and
b), major deviations are found, these can be
corrected by turning the V-controller.
Gas distribution pipe
Gas multi-block
Fig. 20 Differential pressure measuring points (boiler with 11 to 19 sections)
black
blue
blue black
burner
The CO
2
percentage should remain within the tole-
rance mentioned in the table on the boiler.
15. Switch the boiler to part load by selecting option
"Load minimum" with the ' ' button and confirming it
with the ' ' button.
Measure the CO
2
percentage, compare the measured
value with the table value. If it deviates more from the
desired value than the tolerance mentioned in the
table, this value may be adjusted by turning the
N-controller (figure 21 or 22) on the gas multi-block.
If, after turning the N-controller, the CO
2
percentage
corresponds with the table value or in any case
remains within the mentioned tolerance, check the
following points:
a) the combustion quality by looking through the
sight holes in the end sections.
Check that the flames do not blow off ( the burner
surface may evenly burn red-hot.
b) the differential pressure between the measuring
points pF and pG (see fig. 19 or 20). See table on
the boiler for value.
If, when checking the points mentioned under a) and
b), major deviations are found, these can be correc-
ted by turning the N-controller.
The CO
2
percentage should remain within the tole-
rance mentioned in the table on the boiler.
P gas = PF+PG
P air = PL+PF
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 3002 ECO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 3002 ECO in the language / languages: English as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Gas 3002 ECO

Remeha Gas 3002 ECO User Manual - German - 28 pages

Remeha Gas 3002 ECO Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info