8437
28
Zoom out
Zoom in
Previous page
1/36
Next page
28
Remeha
Gas 3002 ECO
11.1 Technical data
Control box: Remeha mbc 3.0
Mains voltage: 230V - 50Hz
Minimum ionization current: 1.0 µA DC
Reaction time of flame protection: 1 sec.
Safety time: 3 sec.
Max. allowable ambient temperature: 60°C
Number of start attempts: 5
Cut-out differential pressure: 50 Pa.
The control box is sensitive to phase/neutral!
The control panel comes with an alphanumeric LCD-
display. The entire starting cycle can be followed on
this display. Using the code connector (boiler recognition
connector) the control unit automatically recognizes the
boiler type. During initial commissioning the control unit
will indicate that it recognizes the boiler type code (if
not: see para. 12). Still, it will ask you to check the type
indicated on the sticker placed on the boiler (next to the
boiler data batch, behind the front panel casing).
See also point 8, para. 11.2.
Attention:
If the boiler takes it’s combustion air from the boiler
room and is commissioned before building works are
completed on the site, particular care must be taken to
avoid dust and dirt particles from the site being drawn
into the boiler house and into the boiler during operation.
Special inlet filters are available for use on the boiler if
the need arises (please contact our technical department
for further information on their use).
11.2 Initial lighting
1. Check the gas connections.
2 Check the electrical connections, phase-neutral-earth
and all earth wires.
3. Check the water level.
4. Check the presetting of the N- and V- controllers
(see fig. 21 for 7 and 9 sections, and fig. 22 for
11 to 19 sections):
5. Switch on the circulation pump and check assembly
position and direction of rotation.
6. Switch on the power supply to the boiler.
7. Activate the main switch on the instrument panel.
11. COMMISSIONING
Fig. 18 Boiler type label
8. Only at initial commissioning:
Select the language in which the texts should appear
on the display using the ' '- and ' ' buttons
and confirm the selection with the ' ' button.
Check the boiler type. Spread over a number of me-
nus, the boiler type specifications will appear on
the display of the control unit. Compare these with
the specifications on the boiler type label (next to the
boiler data batch, behind the front casing, figure 18).
By always confirming the correctness of the specifi-
cations mentioned in a specific menu with the
' ' button, you will travel down the menus until you
get to the main menu (see para. 7.3).
9. Select the service level by travelling down the user
menus using the ' ' button. Enter code 00 12 using
the ' '- and ' ' buttons and confirm it with the
'' button.
10. Now select the option “Service tests” with the
' ' button and confirm it with the ' ' button.
The cursor now can be placed on the following
options: 1.) Boiler on?
2.) Fan on?
3.) Ignition on?
Set the cursor on "Ignition on?" and confirm with the
' '-button. The boiler will now simulate a start, with
closed gas valve. Check the ignition by looking
through the looking glas in the end sections of the
boiler. If you don't see the sparks clearly, check the
position of the ignition electrode.
N
V
Controllers Presetting
0
1,0
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Remeha Gas 3002 ECO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Remeha Gas 3002 ECO in the language / languages: English as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Remeha Gas 3002 ECO

Remeha Gas 3002 ECO User Manual - German - 28 pages

Remeha Gas 3002 ECO Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info