Distance cutting
In some case, it is beneficial cut while
holding the burner sleeve 8c at a height of
1.5 mm to 3 mm above the workpiece. This
reduces the quantity of material that is blown
back into the tip. This makes it possible to
penetrate thicker material strengths. Distance
cutting should be used if penetration or
furrow work is carried out. Furthermore, the
“distance” working technique can be used
when you need to cut sheet metal to
minimise the risk of material splashing back
which could damage the tip.
Perforation
To drill through place the tip approx.
3.2 mm above the workpiece. Hold the
plasma burner at a slight 8 angle to guide
the sparks away from the burner sleeve 8c
and your body. Press the plasma burner
button 8a and lower the tip of the plasma
burner until there is a main cutting arch and
sparks begin to form. Test the perforation on
a test object that is no longer needed and
once there are no problems start drilling
through at the previously defined cutting line
on your workpiece. Check the plasma
burner 8 for wear and tear, cracks or
exposed cable pieces. Replace or repair
them prior to using the device. A badly worn
burner sleeve 8c contributes to the reduction
of speed, voltage and unclean separation.
An indication of a badly worn burner sleeve
8c is an extended or oversized nozzle
opening. The external electrode 8d must not
be recessed by more than 3.2 mm. Replace
it if it is more worn than the specified
dimension. If the protective cap is difficult to
tighten, check the thread.
Using the device / Troubleshooting
Faults Cause of fault Troubleshooting
Indicator lamp
does not lit up? No electrical connection.
ON/OFF switch set to off. Check whether the device is
connected to the socket.
Set switch to ON.
Ventilator does
not work? Power line interrupted.
Power line ventilator faulty.
Ventilator faulty.
Check whether the device is
connected to the socket.
Warning lamp
switches on? Overheating protection
switched on.
Input voltage too high.
Allow device to cool down.
Input voltage according to
type plate.
No output
current? Machine faulty.
Overvoltage protection
activated.
Machine must be repaired.
Allow device to cool down.
Output current
does not
decrease?
Input voltage too low.
Connection cable cross-section
too low.
Observe input voltage
according to type plate.
• Troubleshooting
327358_Plasmaschneider_PPS_40_B2_content_LB6_IE_NI.indb 19 06.09.2019 12:41:03
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Parkside PPS 40 B2 - IAN 327358 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Parkside PPS 40 B2 - IAN 327358 in the language / languages: English, German as an attachment in your email.

The manual is 2,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info