lares 4.0 PROGRAMMING MANUAL
27
rev. 0/2018
Note: the inhibition time is set at 5-second intervals.
If the "always active" parameter is disabled, the detection will take place only when the system is armed (while the
tampering is always active).
• Always active: If this option is not selected, the sensor detects any movements only when the system is switched on.
When this option is enabled, the detection analysis carried out by the sensor is always active.
The option to use if the unum wireless sensor is desired to be used in home automation applications.
After the arming, there may be a maximum delay of 80 seconds before the sensor is fully operational.
• High sensitivity: If this option is disabled, a higher threshold for the immunity to the interferences is introduced in the
detection analysis. Sensitivity is reduced by 30%.
• Reduced range: in optimal conditions, the sensor has a range of about 12 metres. By selecting this option, the range is
reduced to about 6 metres
velum
The parameters available for the velum wireless detectors are:
• Description: the name given to the device (e.g. outdoor sensor in the terrace etc.).
• Serial number: this is the code which identifies the peripheral. Simply update the serial number to acquire the new
peripheral and to keep any previously saved settings if the device is being replaced.
• Supervision: maximum time between two consecutive transmissions.
• Inhibition: this is the time (expressed in seconds) between the transmission of two alarms. To save the battery power,
the detector emits only one alarm during the set interval even if the events that generate the alarms are multiple.
Minimum configurable time: 5 seconds.
Maximum configurable time: 300 seconds.
Note: the inhibition time is set with 5-second intervals.
If the "always active" parameter is disabled, the detection will take place only when the system is armed (while the
tampering is always active).
• Always active: If this option is not selected, the sensor detects any movements only when the system is switched on.
When this option is enabled, the detection analysis carried out by the sensor is always active.
The option to use if the velum wireless sensor is desired to be used in home automation applications.
After the arming, there may be a maximum delay of 80 seconds before the sensor is fully operational.
• High sensitivity: If this option is disabled, a higher threshold for the immunity to the interferences is introduced in the
detection analysis. Sensitivity is reduced by 30%.
• Reduced range: in optimal conditions, velum has a range of 12 metres. By selecting this option, the range is reduced to
about 6 metres.
• Tear-proof: by enabling this option, the MEMS tear-proof (accelerometer) function will be enabled.
• Microwave: enable or disable the microwave (loses the dual technology function where both IR and MW must detect
to generate an alarm).
• Anti-masking: the masking analysis can be set on three levels:
- Disabled: the anti-masking function is disabled.
- Standard: masking within 10 minutes
- Fast: masking within 180 seconds and 3 minutes
nebula
The parameters available for the nebula wireless detectors are:
• Description: the name given to the device (e.g. kitchen smoke detector etc.).
• Serial number: this is the code which identifies the peripheral. Simply update the serial number to acquire the new
peripheral and to keep any previously saved settings if the device is being replaced.
• Supervision: maximum time between two consecutive transmissions.
27


Need help? Post your question in this forum.

Forumrules
1

Forum

ksenia-lares-4.0

Reset search

  • Hi
    We have a message peripherals lost. What does this mean? Submitted on 24-7-2021 at 08:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ksenia Lares 4.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ksenia Lares 4.0 in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info