670163
158
Zoom out
Zoom in
Previous page
1/173
Next page
19
CONTROL COMMAND
19-5
Remote control (CI-V) information (Continued)
Cmd. Sub cmd. Data Description
1A* 05 0064 0000 to
0255
Send/read MOD input level from ACC
(0000=0% to 0255=100%)
0065 0000 to
0255
Send/read MOD input level from USB
(0000=0% to 0255=100%)
0066 00 to 03 Send/read MOD input connector during
DATA OFF
(00=MIC, 01=ACC, 02=MIC/ACC, 03=USB)
0067 00 to 03 Send/read MOD input connector during DATA
(00=MIC, 01=ACC, 02=MIC/ACC, 03=USB)
0068 00/01
Send/read the external keypad setting for
VOICE
*(00=OFF, 01=ON)
0069 00/01 Send/read the external keypad setting for
Memory KEYER (00=OFF, 01=ON)
0070 00/01 Send/read the external keypad setting for
RTTY Memory (00=OFF, 01=ON)
0071 00/01 Send/read the CI-V transceive setting
(00=OFF, 01=ON)
0072 0000 to
0223
Send/read the transceive CI-V Address for
USB to REMOTE in hexadecimal code
(0000=00h to 0223=DFh)
0073 00/01 Send/read the CI-V Output (for ANT)
capability (00=OFF, 01=ON)
0074 00/01 Send/read the CI-V USB port setting
(00=Link to [REMOTE], 01=Unlink to
[REMOTE]) (Read only)
0075 00/01 Send/read echo back setting for CI-V
operation from USB (00=ON, 01=OFF)
0076 00/01
Send/read the USB (serial port) function
setting
(00=CI-V, 01=RTTY Decode)
0077 00 to 03 Send/read data transfer speed for RTTY
decode output
( 00=4800 bps, 01=9600 bps, 02=19200 bps,
03=38400 bps)
0078 00 to 02 Send/read transmission control line setting
for USB
(00=OFF, 01=DTR, 02=RTS)
Different line must be set from both CW
keying and RTTY (FSK)
0079 00 to 02 Send/read CW keying line setting for USB
(00=OFF, 01= DTR, 02=RTS)
Different line must be set from both
transmisson control and RTTY (FSK)
0080 00 to 02 Send/read RTTY (FSK) line setting for USB
(00=OFF, 01=DTR, 02=RTS)
Different line must be set from both CW
keying and transmission control"
0081 0000 to
0255
Send/read LCD unit backlight brightness
(0000=0% to 0255=100%)
0082 00/01 Send/read screen image type (00=A, 01=B)
0083 00/01 Send/read frequency readout font
(00=Basic, 01=Round)
0084 00/01 Send/read peak hold set for meter
*(00=OFF, 01=ON)
0085 00/01 Send/read memory name indication setting
(00=OFF, 01=ON)
0086 00/01 Send/read manual notch width pop-up
indication setting (00=OFF, 01=ON)
0087 00/01 Send/read PBT shifting value display setting
while rotating [TWIN PBT] (00=OFF, 01=ON)
0088 00/01 Send/read IF lter width and shifting value
display setting when the IF lter is switched
(00=OFF, 01=ON)
0089 00 to 03 Send/read screen saver function
( 00=OFF, 01=15 minutes, 02=30 minutes,
03=60 minutes)
0090 00/01 Send/read opening message indication
(00=OFF, 01=ON)
0091 p. 19-9 Send/read opening message contents
(up to 10-character)
0092 00/01 Send/read Power ON Check setting
(00=OFF, 01=ON)
Cmd. Sub cmd. Data Description
1A* 05 0093 00/01 Send/read Display Language
(00=English, 01=Japanese)
0094 20000101
to
20991231
Send/read date setting
( 20000101=2000/01/01 to
20991231=2099/12/31)
0095 0000 to
2359
Send/read time setting
(0000=00:00 to 2359=23:59)
0096 p. 19-11 Send/read UTC offset time
0097 00/01 Send/read scope indication during TX
(00=OFF, 01=ON)
0098 00 to 02 Send/read scope max. hold
(00=OFF, 01=ON)
0099 00 to 02 Send/read scope center frequency set
( 00=Filter center, 01=Carrier point center,
02=Carrier point center (Abs. Freq.)
0100 00/01 Send/read scope marker position setting
during x type scope
(00=Filter center, 01 Carrier point)
0101 00/01 Send/read external monitor signal width
(00=Narrow, 01=Wide)
0102 00 to 03 Send/read avaraging function for spectrum
scope (00=OFF, 01=2, 02=3, 03=4)
0103 00/01 Send/read spectrum display type
(00=Fill, 01=Fill+Line)
0104 p. 19-8 Send/read spectrum ll color
0105 p. 19-8 Send/read spectrum line color
0106 p. 19-8 Send/read spectrum color for peak hold
0107 00/01 Send/read waterfall set for spectrum scope
(00=OFF, 01=ON)
0108 00 to 02 Send/read waterfall speed
(00=Slow, 01=Mid, 02=Fast)
0109 00 to 02 Send/read waterfall height when expanded
scope is selected
(00=Small, 01=Mid, 02=Larger)
0110 00 to 07 Send/read peak color level set for waterfall of
the spectrum scope
( 00=Grid 1, 01=Grid 2, 02=Grid 3, 03=Grid 4,
04=Grid 5, 05=Grid 6, 06=Grid 7, 07=Grid 8)
0111 00/01 Send/read scope waterfall marker auto-hide
(00=OFF, 01=ON)
0112 p. 19-8 Send/read scope edge 1 frequencies for 0.03
to 1.60 MHz band
0113 p. 19-8 Send/read scope edge 2 frequencies for 0.03
to 1.60 MHz band
0114 p. 19-8 Send/read scope edge 3 frequencies for 0.03
to 1.60 MHz band
0115 p. 19-8 Send/read scope edge 1 frequencies for 1.60
to 2.00 MHz band
0116 p. 19-8 Send/read scope edge 2 frequencies for 1.60
to 2.00 MHz band
0117 p. 19-8 Send/read scope edge 3 frequencies for 1.60
to 2.00 MHz band
0118 p. 19-8 Send/read scope edge 1 frequencies for 2.00
to 6.00 MHz band
0119 p. 19-8 Send/read scope edge 2 frequencies for 2.00
to 6.00 MHz band
0120 p. 19-8 Send/read scope edge 3 frequencies for 2.00
to 6.00 MHz band
0121 p. 19-8 Send/read scope edge 1 frequencies for 6.00
to 8.00 MHz band
0122 p. 19-8 Send/read scope edge 2 frequencies for 6.00
to 8.00 MHz band
0123 p. 19-8 Send/read scope edge 3 frequencies for 6.00
to 8.00 MHz band
0124 p. 19-8 Send/read scope edge 1 frequencies for 8.00
to 11.00 MHz band
0125 p. 19-8 Send/read scope edge 2 frequencies for 8.00
to 11.00 MHz band
0126 p. 19-8 Send/read scope edge 3 frequencies for 8.00
to 11.00 MHz band
0127 p. 19-8 Send/read scope edge 1 frequencies for
11.00 to 15.00 MHz band
0128 p. 19-8 Send/read scope edge 2 frequencies for
11.00 to 15.00 MHz band
D Command table (Continued)
158


Need help? Post your question in this forum.

Forumrules
1

Forum

icom-ic-7300

Reset search

  • is there available a wiring pictorial chart for the small internal ic-7300 coaxial jumper cables?
    ie: from the RF unit to the PA board? tnx Sam in Alabam KF4TXQ Submitted on 2-1-2022 at 06:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-7300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-7300 in the language / languages: English as an attachment in your email.

The manual is 24,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info