CONTROL COMMAND
19-3
Remote control (CI-V) information (Continued)
Cmd. Sub cmd. Data Description
00 p. 19-8 Send frequency data (transceive)
01 p. 19-8 Send mode data (transceive)
02 p. 19-8 Read band edge frequencies
03 p. 19-8 Read operating frequency
04 p. 19-8 Read operating mode
05 p. 19-8 Set operating frequency
06 p. 19-8 Operating mode selection for transceive
07 Select the VFO mode
00 Select VFO A
01 Select VFO B
A0 Equalize VFO A and VFO B
B0 Exchange VFO A and VFO B
08 Select the Memory mode
0001 to
0109
Select the Memory channel
*(0001=M-CH01, 0099=M-CH99)
0100 Select program scan edge channel P1
0101 Select program scan edge channel P2
09 Memory write
0A Memory copy to VFO
0B Memory clear
0E 00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
03 F scan start
12 Fine programmed scan start
13
Fine F scan start
22 Memory scan start
23 Select memory scan start
A1
Select F scan span ±5 kHz
A2
Select F scan span ±10 kHz
A3
Select F scan span ±20 kHz
A4
Select F scan span ±50 kHz
A5
Select F scan span ±100 kHz
A6
Select F scan span ±500 kHz
A7
Select F scan span ±1 MHz
B0 Set as non-select channel
B1 Set as select channel
( The previously set number by CI-V is set
after turning power ON, or “1” is selected if
no selection is performed.)
01 to 03 Set as select channel
*(01=SEL1, 02=SEL2, 03=SEL3)
B2 00 to 03 Set for select memory scan
*(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)
D0 Set Scan resume OFF
D3 Set Scan resume ON
0F 00/01 Read Split setting (00=OFF, 01=ON)
00 Turn the split function OFF
01 Turn the split function ON
10* 00 Send/read the tuning step OFF
01 Send/read the 100 Hz tuning step
02 Send/read the 1 kHz tuning step
03 Send/read the 5 kHz tuning step
04 Send/read the 9 kHz tuning step
05 Send/read the 10 kHz tuning step
06 Send/read the 12.5 kHz tuning step
07 Send/read the 20 kHz tuning step
08 Send/read the 25 kHz tuning step
11* 00/20 Send/read Attenuator
*(00=OFF, 20=20dB ON)
13 00 Speech all data with voice synthesizer
01 Speech the operating frequency and S meter
level by voice synthesizer
02 Speech the operating mode by voice
synthesizer
14* 01 0000 to
0255
Send/read the AF level
*(0000=min. to 0255=max.)
02 0000 to
0255
Send/read the RF gain level
*(0000=min. to 0255=max.)
03 0000 to
0255
Send/read the squelch level
*(0000=min. to 0255=max.)
Cmd. Sub cmd. Data Description
06 0000 to
0255
Send/read the NR level
*(0000=0% to 0255=100%)
07 0000 to
0255
Send/read inner [TWIN PBT] position
*
( 0000=max. CCW, 0128=center, 0255=max.
CW)
08 0000 to
0255
Send/read outer [TWIN PBT] position
*( 0000=max. CCW, 0128=center, 0255=max.
CW)
09 0000 to
0255
Send/read CW pitch
*( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A 0000 to
0255
Send/read [RF PWR] position
*(0000=max. CCW, 0255=max. CW)
0B 0000 to
0255
Send/read [MIC] position
*(0000=max. CCW, 0255=max. CW)
0C 0000 to
0255
Send/read [KEY SPEED] level
*(0000=6wpm, 0255=48wpm)
0D 0000 to
0255
Send/read [NOTCH] position
*
( 0000=max. CCW, 0128=center, 0255=max.
CW)
0E 0000 to
0255
Send/read the COMP level
*(0000=0 to 0255=10)
0F 0000 to
0255
Send/read the Break-IN Delay setting
*(0000=2.0d to 0255=13.0d)
12 0000 to
0255
Send/read NB level
*(0000=0% to 0255=100%)
15 0000 to
0255
Send/read the Monitor gain
*(0000=0% to 0255=100%)
16 0000 to
0255
Send/read the VOX gain
*(0000=0% to 0255=100%)
17 0000 to
0255
Send/read the Anti VOX gain
*(0000=0% to 0255=100%)
19 0000 to
0255
Send/read BRIGHT level
*(0000=0%, 0255=100%)
15 01 00/01 Read noise or S-meter squelch status
*(squelch close)
02 0000 to
0255
Read S-meter level
*(0000=S0, 0120=S9, 0241=S9+60dB)
05 00/01 Read various squelch function’s status
*(squelch closed)
11 0000 to
0255
Read PO meter level
*(0000=0%, 0143=50%, 213=100%)
12 0000 to
0255
Read SWR meter level
*( 0000=SWR1.0, 0048=SWR1.5,
0080=SWR2.0, 0120=SWR3.0)
13 0000 to
0255
Read ALC meter level
*(0000=Min. to 0120=Max.)
14 0000 to
0255
Read COMP meter level
*(0000=0 dB, 0130=15 dB,0241=30 dB)
15 0000 to
0255
Read Vd meter level
*(0000=0 V, 0013=10 V, 0241=16 V)
16 0000 to
0255
Read Id meter level
*(0000=0, 0097=10, 0146=15, 0241=25)
16* 02 00 to 02 Preamp
( 00=OFF, 01=Preamp 1 ON, 02=Preamp 2 ON)
12 00 to 03
AGC
*(00=OFF, 01= FAST, 02= MID, 03=SLOW)
22 00 to 01 Noise blanker *(00=OFF, 01=ON)
40 00 to 01 Noise reduction *(00=OFF, 01=ON)
41 00 to 01 Auto notch function *(00=OFF, 01=ON)
42 00 to 01 Repeater tone *(00=OFF, 01=ON)
43 00 to 01 Tone squelch *(00=OFF, 01=ON)
44 00 to 01 Speech compressor *(00=OFF, 01=ON)
45 00 to 01 Monitor function *(00=OFF, 01=ON)
46 00 to 01 VOX function *(00=OFF, 01=ON)
47 00 to 02 BK-IN function
*( 00=BK-IN OFF, 01=Semi BK-IN ON,
02=Full BK-IN ON)
48 00 to 01 Manual notch function *(00=OFF, 01=ON)
4F 00 to 01 Twin Peak Filter *(00=OFF, 01=ON)
Can be turned ON only when Mark and Shift
are set to 2125 Hz and 170 Hz, respectively.
D Command table
156


Need help? Post your question in this forum.

Forumrules
1

Forum

icom-ic-7300

Reset search

  • is there available a wiring pictorial chart for the small internal ic-7300 coaxial jumper cables?
    ie: from the RF unit to the PA board? tnx Sam in Alabam KF4TXQ Submitted on 2-1-2022 at 06:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-7300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-7300 in the language / languages: English as an attachment in your email.

The manual is 24,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info