590611
18
Zoom out
Zoom in
Previous page
1/28
Next page
18 GMC-I Messtechnik GmbH
11 Capacitance Measurment
Make sure that the device
under test is voltage-free.
Interference voltages distort
measurement results!
Turn the rotary switch to the
“F” position.
Connect the (discharged!)
device under test to the
and V jacks with the
measurement cables.
Zero Balancing in the 30 nF Measuring Range
Intrinsic capacitance at the measuring instrument and cables can be eliminated
for the measurement of small capacitance values in the 30 nF range by means of
zero balancing:
Connect the measurement cables to the measuring instrument without a
device under test.
Briefly press the FUNC key.
The instrument acknowledges zero balancing with an acoustic signal and
00
.00 ” and the ZERO symbol appear at the LCD. Capacitance measured
at the moment the key is pressed is used as a reference value (max.
2000 digits). This value is automatically subtracted from all subsequently
measured values.
Zero balancing can be cleared:
by pressing and holding the FUNC key, after which clearing is acknowledged
by an acoustic signal,
by switching the instrument off.
12 Frequency Measurement – Duty Cycle Measurement
Turn the rotary switch to the Hz position.
Apply the measured quantity as described under voltage measurement.
Smallest measurable frequencies and maximum allowable voltages are
listed in chapter 15, “Characteristic Values”.
The pulse-period ratio can be ascertained for square-wave signals with the duty
cycle measurement.
Briefly press the multifunction key twice (FUNC). The instrument is switched
to duty cycle measurement. The duty cycle, i.e. the pulse duration of a sig-
nal as a percentage, is displayed at the LCD.
Note
The applied frequency must remain constant during duty cycle measurement.
+
Duty Cycle (%) = ——————— • 100
Pulse Duration
Period
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAport 40S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAport 40S in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info