588931
30
Zoom out
Zoom in
Previous page
1/38
Next page
30
Current air pressure
Indicates the current air pressure (reduced).
Value range: 900,0 – 1100,0 Hpa (= Hecto-Pascal)
Weather record (air-pressure record)
Subfunction of “current air pressure”
Indicates the course of air pressure during the last 24 hours and the forecast for the next 24 hours.
In the course of this, the lower display shows the measured air pressure and the upper display the
moment in which the measurement was made, each for 3 sec.
Current climb / sink (variometer)
Indicates the current climb or sink in meters per minute, resp. in feet per minute.
The arrow in the display shows the direction of change in altitude. This function is of interest for moun-
taineers, bike riders, downhill and cross-country skiing; within limits it is also suitable for use in hang-
gliding and paragliding.
Value range: 0 - 1000 m/min, resp. 0 - 3000 ft/min (exactitude up to 5 m/min, resp. 20 ft/min)
Attention: Due to technical reasons the correct altitude is displayed with a temporal delay of some
seconds after activating the program.
Average climb / average sink
Subfunction of “current ascent / descent
The upper display shows the average climb and the lower display the average sink since the beginning
of the current tour.
Value range: 0 - 1000 m/min, resp. 0 - 3000 ft/min (exactitude up to 5 m/min, resp. 20 ft/min)
Note: These functions allow to calculate the remaining time to reach the next summit or valley. In order
to do so the indicated value is multiplied with 60 which equals the meters in altitude covered per hour.
Maximum climb / sink
Subfunction of “current climb / sink”
The upper display indicates the maximum climb and the lower display the maximum sink since the
beginning of the current tour.
Value range: 0 - 1000 m/min, resp. 0 - 3000 ft/min (exactitude up to 5 m/min, resp. 20 ft/min)
Number of climbs and sinks
Subfunction of “current climb/ sink”
The upper display shows the number of climbs and the lower display the number of sinks since the
beginning of the current tour.
Value range: 0 - 1000
Note: The
HAC5 counts the number of climbs/ sinks of altitude differences from 50 m, resp. 164 ft since
this function was primarily thought to be used in downhill skiing and biking (= users of lift).
Current ascent / descent
Indicates the current ascents / descents covered so far in percent.
Value range: 0 - 99 %.
Attention: Due to technical reasons the correct percentage is displayed with a temporal delay of some
seconds after the beginning of the change in altitude.
Average / maximum ascent
Subfunction of “ascent / decent”
The lower display shows the average ascent and the upper display the maximum ascent since the
beginning of the current tour.
Value range: 0 - 99 %.
Average / maximum descent
Subfunction of “ascent / decent”
The lower display shows the average descent and the upper display the maximum descent since the
beginning of the current tour.
Value range: 0 - 99 %.
Temperature
Indicates the current temperature. In case the HAC5 is worn on the wrist, the measured temperature
can be subject to adulteration due to body heat.
Minimum and maximum temperature
Subfunction of “temperature”
The upper display shows the maximum temperature and the lower display the minimum temperature
measured during the current tour.
Note: The following major functions “calorie consumption” and “fat burn” are only calculated when
records are made.
Weather record
(air-pressure record)
Average climb /
average sink
Current air pressure
Current climb/ sink
(variometer)
Tour
11
Ø-Vario
13
Tour
Maximum climb /
sink
Tour
15
Max. Vario
19
Tour
Number of climbs
and sinks
Average /
maximum ascent
Current ascent /
descent
Up
1
Vario
0
Down
Ø
7
Ascent
12
Max.
Average /
maximum descent
Temperature
Ø
5
Descent
9
Max.
B
A
A
Minimum and
maximum temperature
Max.
28 °C
Temperature
21°C
Min.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ciclo HAC 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ciclo HAC 5 in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ciclo HAC 5

Ciclo HAC 5 Additional guide - English - 4 pages

Ciclo HAC 5 Additional guide - German - 4 pages

Ciclo HAC 5 Quick start guide - German - 2 pages

Ciclo HAC 5 User Manual - German - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info