Settings:
The settings made during the installation are stored here, or it is
possible to reload the production or the installation settings.
Three main options are accessible:
„Loading of settings“ – means, that you can reset the original settings
„Saving of settings“ – stands for the final input of the burner settings, made by the installator.
This eases browsing of settings, if it would come to too many parameter changes.
„Production settings“ – are the original settings, that can be reloaded again.
Log:
All the errors are saved and displayed here, together with the
frequency of their incidence. Also the final number of the ignition
trials is here to be read.
There are four options: number of errors:
„Number of errors“ – displays every error code individually, e.g. E–CODE 10(X).
See the page for codes and explanation.
„Number of the first ignitions“ – displays, how many times did the ignition run.
„Number of the second ignitions“ – displays, how many second ignition trials were made by
burner (i.e. how many times did first trial fail).
„Last errors“ – displays the codes of errors in the order according to their incidence. It eases the
troubleshooting.
10 MAINTENANCE OF THE BOILER
During the boiler life is necessary to make maintenance to work properly. The maintenance fre-
quency depends on boiler frequency and utilization when is boiler in operation process.
Maitenance of the heating system with the boiler
It is necessary to check, eventually to refill the water in the heating system at least 1× in 14 days.
If the boiler is out of order during the winter period and danger the water could freeze in the
heating system, then the water should be replaced with an antifreeze mixture approved by the
producer or it should be discharged out of the system. Normally should be the water discharged
only in urgent cases and for ash short time as possible. At the end of the heating season it is nec-
essary to clean the boiler properly and to replace the damaged parts. Twice a year it is necessary
to dismantle the fan, to clean the radial impeller and to clean the fan air chamber.
Adjusting the hinges and exchange of the sealing cord of the door
After a particular period is the sealing cord in the door pressed. To ensure its tightness is neces-
sary to change the position of the door by screwing the door hinges. When the cord completely
loses its elasticity, or the hinges can no longer be moved into the direction to the boiler, it must
be replaced. Undo the worn sealing cord by the screw driver and clean the groove, where it was
laid. Take the new sealing cord and put its ends into the horizontal parts of the groove. Use your
hand, eventually a hammer to press the cord into the groove around the door. Loosen hinges
and find the correct position of door hinges to the door.
MENU/SETUP
ENTER < > EXIT
LOG
ENTER > EXIT
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info