810510
58
Zoom out
Zoom in
Previous page
1/100
Next page
57
EN
Replacement of the nozzle
The nozzle is laid in the boiler body on the holder. In the bottom part is the nozzle sealed by
a boiler sealant and in the upper part there is a sealing cord around. When replacing the nozzle,
remove the sealing cord from the groove by a screw driver. Take the nozzle out and clean the
holder properly from tar and old sealant. Then treat the bottom part of the nozzle with the fire-
proof sealant and put the nozzle on the clean holder with the arrow towards the rear boiler part.
There should be the same space on the both sides of the nozzle. Take the new set of the sealing
cords for the nozzle and press it lightly into the gap just around the nozzle.
10.1 BOILER CLEANING
The boiler must be cleaned regularly to operate correctly and reach the required comfort and
durability.
ATTENTION: The boiler has to be cleaned regularly and properly, otherwise there is a risk
of its wrong functionality, shortened service life or damage! The warranty is not valid if
the boiler is not regularly and sufficiently cleaned!
Cleaning the boiler should be carried out regularly and properly every 3 – 5 days because sedi-
mentation in the loading and combustion chamber with condensation and tar significantly re-
duce the life, power and efficiency of the boiler. If is bigger amount of ash than is not enough
space for burning out of fuel and this can damage the holder of ceramic jet as well as the whole
boiler. By boiler cleaning at first turn on the fan, open the feeding door and wipe the ash
through a slot into bottom space. Long pieces of unburned fuel leave in the hopper. Move
sometimes with the exchanger cleaning lever on the left side of the boiler. Ash and smoke put
out after opening the bottom cleaning hole. After opening the bottom door, clean the bottom
space. Interval of cleaning depends on the quality of wood (moisture), heating intensity, chim-
ney draft and other factors. We recommend to clean the boiler 1 time per week. Fireproof clay
do not take out by cleaning. Check the cleaning channel of primary and secondary air or cleaned
by scraping holes and blowing. It influences the output and quality of burning.
ATTENTION
:
Regular and proper cleaning is important to ensure the permanent output
and service life of the boiler. The warranty is not valid if the boiler is not sufficiently
cleaned and damaged.
The frequency of cleaning the particular boiler parts is given in the table below:
-
Cleaning*
Daily
Weekly Annually
Ash removing
Space around the ash tray
Space under the exchanger
Lever of turbulators 5 – 6×
Flap 1×
Space of the fan
Radial impeller of the fan
* The minimum recommended intervals of cleaning. They can be shorter, according to the intensity of
operation.
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info