ALIGNMENT PROCEDURE
To align the mirrors:
1. Loosen locking screw (Fig. 1.3, page 1) on the mirror holder until the mirrors can be
adjusted by hand.
2. Point the mirror as accurately as possible towards its corresponding mirror on the
opposite pillar. Over large distances, use the periscope. A flashlight can be used to help
locate the opposite pillar.
3. Tighten the locking screw of the mirror until it is no longer possible to adjust it by hand.
4. Adjust the mirror on both devices with the key until the alarm LED (Fig. 1.6) switches to
dark.
Range of adjustment
The parabolic mirrors can be adjusted horizontally by
approximately ?90° and vertically approximately ?15°.
Consequently, the devices do not have to point in only one
direction. A spanner has been included to make fine
adjustments.
Note that when installing the devices inside pillars, the
adjustment range is reduced.
Mechanical alignment by using a periscope
Insert the periscope support into the top pair of mirrors of the
transmitter and, looking through the periscope, carefully position
the mirror so that you can see in its center the corresponding
mirror on the opposite pillar. Repeat for the other mirrors of the
transmitter and receiver. If there is a large distance between the
transmitter and receiver, use a flashlight to help locate the
opposite pillar.
Electro-optical alignment
To precisely align the receiver use the alignment control device (available as an accessory) or an oscilloscope
which can be connected to the test points SIG (Fig. 1.9) and GND (Fig. 1.11) (for an older version of the
alignment control device, change SIG and GND). An optional radio controlled module can be adapted to clamp
RF (Fig. 1.4). The alignment is correct when a maximum number of the LED’s light up on the alignment control
unit.
LED-indicator Alignment result
1 LED Insufficient incident IR beam
(re-adjust transmitter)
2-3 LED Barely sufficient IR beam
4-5 LED Sufficient IR beam
6-8 LED Excellent IR beam
Alignment control unit
1 2 3 4 5 6 7 8
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech DO505 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech DO505 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info