ATTENTION!!! In case of finding out that the nozzle does not spray the water although the
pump is on, check if the back tank is properly assembled (push it strong in),
and assembling the stub in the valve at the base. In case of difficulties with
fitting lubricate the seating of back tank valve and the stub sealing.
Clean the carpet so, that you do not step on the cleaned surface during cleaNing or just after.
ATTENTION!!! The vacuum cleaner is equipped by the manufacturer with one of the a/m
cleaning agents only.
After cleaning the part of the carpet make a break and dry it with forward and backward movements
of the nozzle. Repeat the activities until the whole surface of the carpet is dried.
When spraying is finished switch the pump off and press for a moment the button adjusting the
water flow to the nozzle, to release the pressure.
In case of old or especially difficult stains, damp the place with cleaning agent recommended
by ZELMER S.A., up to the moment the foam appear. Then leave for a while and next suck it
out with the vacuum cleaner.
ATTENTION!!! Do not allow the carpet soaking. It can cause the permanent deformation
(rucking).
91
PLAIN FLOORS CLEANING
Fit the brush strip on the nozzle.
Press the pump on/off button in and switch the vacuum cleaner on (as in case of carpets).
Press the adjusting button at the hose handle to adjust the
water flow to the nozzle.
ATTENTION!!! In case the spraying nozzle is blocked disassemble the
nozzle from the tube and clean (blow) the duct, or replace
the nozzle with a new one.
The set of spare nozzles is attached to the accessories
Nozzle exchange
1. Remove the spraying element and the ring ø 5,6 x 1 from the
big (or small) spraying nozzle,
Press the sprayer with your thumb according to the mark on the nozzle housing.
2. Lubricate the new sprayer including the ring and insert it into the nozzle inlet up to the moment
the hooks are locked.
Move the nozzle along the cleaned surface with forward and back ward movements.
Stop the spraying after clearing the part of the floor and suck the solution in, making slow
movements of the nozzle in your direction, until all solution is collected from the floor.
Continua it until all the floor is cleaned and dried.
When spraying is finished switch the pump off and press for a moment the button adjusting the
water flow to the nozzle, to release the pressure.
If you preformed wet clearing (picking up wet dirtiness) before finishing operation in the final
stage, suck in abort 1–2l of clean water in order to flush the tubes and hose, and then suck in
the air for a while, in order to dry them.
AFTER OPERATION
Switch the vacuum cleaner off and unplug it from the mains supply outlet.
Rewind the cord pressing the rewind button. Hold the plug when rewinding, do not
allow the cord to get entangled and the plug to bump the casing.
Turn the ending of the hose up to the position where the tops
marks on the hose ending and tank cover each other and remove
the hose from the tank.
Remove the hose stub from the base.
Press the button and disassemble the tubes.Disassemble the
hose and nozzle similar way.
91


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer 619 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer 619 in the language / languages: English, Polish as an attachment in your email.

The manual is 3,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info