Each chimney connector or chimney connector section must
be installed to the stove flue collar and to each other with the
male (crimped) end toward the stove. This prevents any
amount of condensed or liquid creosote from running down the
outside of the pipe or the stove top. The flue collar connector
should be secured with sheet metal screws to ensure that the
sections do not separate. For the best performance the
chimney connector should be as short and direct as possible,
with no more than two 90° elbows. The maximum horizontal
run is 36” and a recommended total length of chimney
connector should not exceed 10 feet. Always slope horizontal
runs upward ¼” per foot toward the chimney. Note the
chimney connector pipe should not pass through an attic or
roof space, closet or similar concealed space, or a floor or ceiling.
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE OR AIR DISTRIBUTION
DUCT OR ANY SYSTEM SERVING ANOTHER APPLIANCE.
For venting vertically into a Class A chimney, single wall black steel pipe (at least 24 gauge and
6” in diameter) must be used in the room where the stove is installed. Refer to the manufactur-
er’s instructions for the connection to the listed chimney.
For venting directly into a masonry chimney or through a thimble, the top of the single wall pipe
must be at least 18“ (46 cm) below a combustible ceiling and conform to NFPA 211 or
CAN/CSA-B365 guidelines and methods.
For rear venting or other not listed configurations, consult the local building codes and follow the
NFPA 211 or CAN/CSA-B365 guidelines. To install the collar on the back, first unscrew the rear
plate of the Twinfire stove and attach the collar to the back of stove. Then, attach the first stove
pipe section to the connector pipe with screws, and replace the rear wall plate.
If the chimney connector is fitted with a
baffle, it must be manually operated, visi-
bly placed for ease of use, and must not
close completely. Consult your chimney
expert if you have any questions. Make
sure that there is easy access to the
chimney cleanout door. Floor protection is
required under the chimney connector and
2" (51cm) beyond each side.
Chimney
Flue
Masonry
Insulated
Chimney
Connector Pipe
18”(46cm)
below
ceiling
Min.
2”(5cm)
Min.
2”(5cm)
6


Need help? Post your question in this forum.

Forumrules
1

Forum

xeoos-twinfire

Reset search

  • Hi, how do you replace the fire bricks in the upper chamber of a Xeoos harmony twin fire wood burner Submitted on 6-10-2022 at 20:08

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Xeoos Twinfire at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Xeoos Twinfire in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Xeoos Twinfire

Xeoos Twinfire User Manual - German - 20 pages

Xeoos Twinfire User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info