706614
4
Zoom out
Zoom in
Previous page
1/15
Next page
Revised 10-006 Page 4 of 15
Operational Description and Approvals
The patented Twinfire
®
-System of xeoos
®
is based on the principle of gasification with the use of
the furnace. The four Twinfire models are tested by OMNI-Test Laboratories, Inc. of Portland,
Oregon and are listed to UL 1482 and ULC S627. They are also EPA certified and meet the
more stringent WA State Environmental standards.
All the products have been rated to 93% efficiency.
The upper combustion chamber is set to the desired heat output from the primary air control
connected to the upper combustion chamber. In this process the energy efficient wood gases
are drawn through the flames and burned with secondary air also at high temperatures
(> 1832°F or 1000°C). Then the two-flame combustion in the upper and lower chambers can be
seen through the large Robax-ceramic glass window.
With the second combustion level, the Twinfire reaches a very high degree of efficiency. This
means a great heating output at low fuel consumption and with less ash. The two elements that
control the combustion concept and the heating output are:
1. The door handle with its double-function makes locking the door and starting the Twinfire
System possible. The setting “heat up” exhausts the gases like a normal stove directly
upward. Switching to the second setting starts the low-emission and efficient operation of
the gasification furnace.
2. By adjusting the Twinfire Air Control handle, the amount of primary air regulates the heat
output (ranging from 40 to 100 percent of the nominal output).
Door Handle /
Twinfire-Starter
Lower Combustion
Chamber
Upper Combustion
Chamber
Twinfire-Grate
4


Need help? Post your question in this forum.

Forumrules
1

Forum

xeoos-twinfire

Reset search

  • Hi, how do you replace the fire bricks in the upper chamber of a Xeoos harmony twin fire wood burner Submitted on 6-10-2022 at 20:08

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Xeoos Twinfire at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Xeoos Twinfire in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Xeoos Twinfire

Xeoos Twinfire User Manual - German - 20 pages

Xeoos Twinfire User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info