706614
5
Zoom out
Zoom in
Previous page
1/15
Next page
Revised 10-006 Page 5 of 15
Installation of the Stove
Heating Capacity and Space Requirements
The room-heating-capacity is highly dependent on the room’s location and interior as well as on
the operation method. In a newer air-tight building be prepared to calculate your heat demand.
In older buildings, the nominal heating capacity of approximately 27kBTU’s (8 kW’s) heats an
area from 430 - 1,076 ft
2
(40 -100 m
2)
based on various conditions.
Outside Air Supply
Ensure that there is sufficient combustion air in the room in which the stove is installed, and that
there is an adequate supply of combustion air to the stove, which can be sourced from another
room or from an outside air supply. Rooms with negative pressure (e.g. use of exhaust fan) or
newer air-tight buildings are particularly suited for air supply from outside. An outdoor air supply
to the Twinfire is available as an option, and should be installed by a qualified person.
Connection to the Chimney
The Twinfire stove can be connected from top or rear. The diameter
of the stove pipe is 6” (15.2 cm). Do not use connector pipes and
chimneys with smaller clearance diameters or less than 24 gauge
steel. It must be installed using a Class A UL 103 HT approved facto-
ry-built chimney system or a code-approved masonry chimney with a
flue liner. Aluminum and galvanized steel pipe is not acceptable. In
Canada, the installation must conform to NFPA 211 or CAN/CSA-
B365. The chimney must extend through the roof at least 3’ (1m), and
2’ (6 m) above any structure within 10’ (3 m). The condition of the
chimney and height is very important. We suggest a total minimum
height of 10’ (3 m).
To reach the rated heat capaci-
ty, the minimum delivery pres-
sure of the chimney must be 10
to 15 Pa (1.0 to 1.5 mm WC).
Follow the rules and regula-
tions in your local area.
IT IS VERY IMPORTANT TO ENSURE THAT YOUR CHIMNEY HAS A GOOD
DRAFT. YOUR DEALER OR CHIMNEY SWEEP WILL BE ABLE TO GUIDE
AND ADVISE YOU ON YOUR CHIMNEY CONDITIONS.
Required Installation Components
A
Chimney cap
B
Insulated chimney
C
Storm collar
D
Roof flashing
E
Ceiling support box
F
Chimney connector pipe
A
B
C
D
B
E
F
5


Need help? Post your question in this forum.

Forumrules
1

Forum

xeoos-twinfire

Reset search

  • Hi, how do you replace the fire bricks in the upper chamber of a Xeoos harmony twin fire wood burner Submitted on 6-10-2022 at 20:08

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Xeoos Twinfire at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Xeoos Twinfire in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Xeoos Twinfire

Xeoos Twinfire User Manual - German - 20 pages

Xeoos Twinfire User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info