697438
40
Zoom out
Zoom in
Previous page
1/64
Next page
40
Commissioning
GREENSPRING CWi47 – 6 720 646 322 (2015/04)
Loosen screw inside left test point fitting (do not remove)
and connect gas pressure gauge tube to test point.
Fig. 55 Gas pressure test point (left test point)
Static Pressure Test
Turn gas supply back on.
Record static gas pressure reading in Table 16.
Operating Pressure Test
Press ON/OFF button to turn off the appliance.
Press and hold "Program" button and press ON/OFF button
to turn appliance ON (Fig.
56).
Fig. 56 Gas setup mode
As soon as '188' is displayed, release "Program" button
, and the display reads P2.
Press or until P1 appears.
For inlet gas pressure adjustment see values in Table 17:
Turn on high volume of hot water flow (at least 15 l/m) and
burner will light. If heater display reverts to P2, open more
hot water draw off points to allow sufficient flow. Press
until P1 reappears on the display.
Operate all other gas appliances on same gas supply at
maximum output.
Record lowest operating gas pressure reading in Table 16.
Gas pressures lower than 20 mbar for Natural Gas or 27-
30/37 mbar for LPG will result in reduced temperature rise
to the hot water being used, reduced hot water volume,
possible error code faults and must be corrected.
Check gas pipes dimensions.
Static Gas Pressure Reading
Pressure: ___________________ Date: ___________
Operating Gas Pressure Reading
Pressure: ___________________ Date: ___________
Table 16
6720608920-16.1AL
NOTE: While in this mode, the appliance will
run constantly at maximum output and allow
maximum water flow.
Gas type NG Propane
mbar 20 37
Table 17
6720608920-17.1AL
+
+
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GREENSPRING CWi47 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GREENSPRING CWi47 in the language / languages: English as an attachment in your email.

The manual is 5,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info