39
Commissioning
GREENSPRING CWi47 – 6 720 646 322 (2015/04)
Natural gas
The water heaters are designed for use with natural gas (G20)
and are pre-commissioned for operation with that gas type.
LPG
The water heaters are designed for use with LPG (G31) and are
pre-commissioned for operation with that gas type.
Check the gas supply working pressures in the system
conform to the readings shown in the table below:
Fig. 53
Fig. 54
9.2 Measuring gas pressure
Confirm gas pressure after installation.
Connecting gas pressure gauge
Shut off gas supply.
Remove the front cover (Fig. 24).
Ensure that the inlet pressure is satisfactory
with all other gas appliances working.
NOTICE:
Ensure that the gas inlet pressure is
satisfactory with all other gas appliances
working.
Do not continue with the other checks if
the correct gas inlet pressure can not be
achieved.
Natural gas
Allowed mbar pressure drop
meter /
regulator
across
pipework
gas
isolation
valve
heater
inlet
across
heater
gas
control
valve
19 - 23 1 0.5 18 - 22 2 16 - 20
Table 14
Heater inlet
valve
19 - 23 mbar
18 - 22 mbar
16 - 20 mbar
1 mbar
drop
2 mbar
drop
Natural Gas
< 3mbar
difference
6720646322-26.1V
LPG
Allowed mbar pressure drop
meter /
regulator
across
pipework
gas
isolation
valve
heater inlet across
heater
gas
control
valve
32 - 45 2.5 0.5 29.5 - 42.5 2 27.5 -
40.5
Table 15
valve
L.P.G.
< 4.5mbar
difference
32 - 45 mbar
29.5 - 42.5 mbar
27.5 - 40.5 mbar
Heater inlet
6720646322-27.1V
2.5 mbar
drop
2 mbar
drop
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GREENSPRING CWi47 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GREENSPRING CWi47 in the language / languages: English as an attachment in your email.

The manual is 5,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info