Scope of Delivery
Multimeter with protection rubber frame
Compound 9V battery
K-type thermosensor (up to max. 200°C)
Multipurpose plug for the K-type thermosensor
Safety measuring wires red and black
Safety alligator clips
Inductive speed meter
Operating Instructions
Display Indications and Symbols
HOLD stands for data hold; the measuring value is kept (e.g. for the
record) until the "HOLD" button is pressed anew or the multi-
meter is switched off.
REL stands for the relative value measurement (=reference measu-
rement)
Auto stands for "automatic measuring range selection"
OL stands for overload = overload, the measuring range has been
exceeded
BAT battery replacement symbol; please replace the batteries
immediately to avoid measuring errors!
symbol for the diode test
symbol for the acoustic continuity tester
AC alternating size for voltage and current
DC direct size for voltage and current
V volt (unit of electric potential)
A ampere (unit of electric current)
Hz hertz (unit of frequency)
Ω ohm (unit of electric resistance)
F farad (unit of capacity)
°C grade centigree (unit of temperature)
% indication of the duty cycle of a signal in %
n nano (exp.–9)
µ micro (exp.–6)
m mill (exp.-3)
k kilo (exp.3)
M mega (exp.6)
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft AT-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft AT-200 in the language / languages: English, German, French as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info