38 D-307500 PowerMaster 360 Installer's Guide
PLINK GPRS
The GSM/GPRS module is capable of communicating with the monitoring station
receiver by GPRS or SMS channels.
The GPRS channel is always enabled. If it fails, the GPRS module will try to
communicate via SMS.
Limited (default)Plink uses GPRS only when the wired Ethernet channel is not
functional, and for event and film reports (keep-alive and NTP mechanism will not use
the GPRS channel).
Unlimited – Plink uses GPRS only when the wired Ethernet channel is not functional,
and for any other purpose.
Disable – Plink does not use GPRS for event reports, film reports, or the home
automation app.
4.6.3 Configuring event reporting to monitoring stations
The PowerMaster-360 control panel is designed to report alarm, alerts, troubles and other events and messages to two
Monitoring Stations C.S.1 and C.S.2 via Cellular i.e. GPRS (IP) & SMS or Broadband IP communications channels. In
this section you configure and define all parameters and features required for the reporting of the event messages to
Monitoring Stations such as:
The events reported to each of the two Monitoring Stations C.S.1 and C.S.2 and corresponding backups.
The communication means (channel) used for the reporting and the backup means (channel) in case of failure.
The customer's (subscriber) account number(s) to be reported to each Monitoring Station.
The IP addresses, SMS numbers and reporting formats of the corresponding alarm receivers at the two Monitoring
Stations, C.S.1 and C.S.2, and the number of reporting retry attempts in case of failure to report.
The communication Auto Tests and communication Fail reports.
The reporting of certain system function events such as Confirmed Alarm, Recent Close, Zone Restore and System
Not-Used.
04:COMMUNICATION  3:C.S.REPORTING  MENU required
Enter 3:C.S.REPORTING, select the menu you require to configure (see guidance above and in section 4.6.1), then
refer to the table below which provides you with detailed explanations and configuration instructions for each option.
Option
Configuration Instructions
01:REPORT EVENTS
Define which events (i.e. Alarms (alrm); Open/close (o/c); Alerts (alrt); All events (all);
Maintenance and Troubles) will be reported to the Monitoring Stations.
The minus (-) symbol means less/except, for example all (-alrt) means all events except
alerts.
The asterisk () is a separator between events reported to Monitoring Station 1 (C.S.1) and
events reported to Monitoring Station 2 (C.S.2). For detailed and more complete explanation
see the Event Reporting Chart at the end of this section.
Options:
all-o/c backup (default)
all-o/co/c
disable report
all all
all(-alrt)alrt
all backup
all-o/call-o/c
alrmall(-alrm)
Note: Alarm events (alrm) have highest priority and Alert events (alrt) have lowest priority.
02:1st RPRT CHAN
If the system is equipped also with Cellular communicators, you must define which of the
communicating channels (i.e. Cellular or Broadband) the system will use as the main channel
(i.e. 1st priority) for reporting event messages to Monitoring Stations.
Enter the 1st RPRT CHAN; option and define which of the communication channels the system
will use as the main reporting channel.
Options: broadband first (default); disable; and cellular first.
Important:
If the selected main reporting channel fails, the system will use the other
communication channel to report event messages to Monitoring Stations. If none
is selected, the reporting to Monitoring Stations will be disabled.
05:DUAL REPORT
Define whether or not to report events using broadband and cellular communication channels.
Options: disable (default); broadbnd & cell.
11:RCVR1 ACCOUNT
Enter the respective 1st Account (subscriber) number (11:RCVR 1 ACCOUNT) that will identify
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic Powermaster-360 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic Powermaster-360 in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info