580332
28
Zoom out
Zoom in
Previous page
1/74
Next page
MENUS AND FUNCTIONS
D-304829 PowerMaster-10/30 G2 User's Guide 27
B.5 Programming the Duress Code
*
A. To Program the Duress Code
Additional Information (section B.5)
1
For detailed instructions on how to select the setting options – refer to sections A.1 and A.2.
2
The display shows the default duress code (2580).
3
Do not set the duress code the same as an installer or user code.
4
To end this session and to select other menu options or to quit programming – follow the instructions in
section A.2.
B.6 Add / Delete Proximity Tags
A proximity tag may be assigned to each of the PowerMaster-10 G2 user codes 1-8 / PowerMaster-30 G2 user
codes 1-32 that can be used instead of the user codes to perform a variety of functions, for example, arming,
disarming, reading the event log, etc.
Whenever a user code is required you can simply present a valid proximity tag instead of entering the user
code. Each tag should be assigned with a serial No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) that
corresponds to the User Code No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) and enrolled into the
system correspondingly.
The partition
*
authorization of the tags is identical to their corresponding user codes. For example, proximity tag
3 is assigned to user code 3.
Here you can add (enroll) new proximity tags or delete tags as required.
Carefully read the section titled "Additional Information" according to the indicated references
1
etc – see
table at end of this section.
A. To Add (Enroll) a Proximity Tag
1.
PROXIMITY TAGS
Enter the [USER SETTINGS] menu, select the [PROXIMITY TAGS] option
and press .
1
2. ADD NEW TAG The display will read [ADD NEW TAG].
3
To begin the process of enrolling a new proximity tag press
.
3.
ENROLL NOW or
ENTR ID:xxx-xxxx
Present the proximity tag to the control panel within the timeout period.
4.
DEVICE ENROLLED
If enrollment was successfully completed, a "Happy Tune" sounds and
*
Duress Code is not applicable for UL installations
A duress (ambush) alarm message can be sent to the Monitoring Station if you are forced to disarm the system under
violence or menace. To initiate a duress message, you must disarm the system using a duress code (2580 by default).
1.
DURESS CODE
Enter the [USER SETTINGS] menu, select the [DURESS CODE] option and
press .
1
2.
DURESS CODE 2580
At the blinking cursor position, key in the Duress Code you wish to program,
for example, 6973.
2, 3
3.
DURESS CODE 6973
When the duress code you wish to program appears on the display, press
.
Return to step 1 A "Happy Tune"
sounds. The display confirms the saved code.
4
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info