580332
30
Zoom out
Zoom in
Previous page
1/74
Next page
MENUS AND FUNCTIONS
D-304829 PowerMaster-10/30 G2 User's Guide 29
Additional Information (section B.6)
1
For detailed instructions on how to select User Settings – refer to sections A.1 and A.2.
2
The display shows the first enrolled Tag (Tag No.1) of the 8 tags (PowerMaster-10 G2) / 32 tags
(PowerMaster-30 G2).
3
To abort enrollment press the button.
4
If the tag was previously enrolled in the system, the PowerMaster display reads [
ALREADY ENROLLED
]
and then switches to the name of the tag alternating with its ID number.
5
If Partition is enabled, continue to step 6.
6
You can now enroll another proximity tag. You can also select another option in the User Settings menu
(see section A.1), or quit programming (see section A.2).
7
If no proximity tag is enrolled in the system, the display reads [
NO EXISTING DEV.
].
8
To abort the procedure, press the
button.
9
This setting can be performed only after completing steps 1 - 5 of section B.5A.
10
The
symbol now appears next to the newly selected Partitions.
11
You can now repeat steps 2 - 7 to program or edit another Proximity tag.
12
You can now add or delete another proximity tag. You can also select another option in the User Settings
menu (see section A.1 and section A.2), or quit programming (see section A.3).
B.7 Add / Delete Keyfob Transmitters
A portable keyfob transmitter may be assigned to each of the PowerMaster-10 G2 user codes 1-8 /
PowerMaster-30 G2 user codes 1-32 for better, quicker and safer arming/disarming and other control functions.
Each keyfob should be assigned with a serial No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) and
enrolled into the system correspondingly.
Partition Option (For information about Partition option - see Appendix B)
If the Partition option is enabled in the control panel, each of the 8 keyfobs (PowerMaster-10 G2) / 32 keyfobs
(PowerMaster-30 G2) can be authorized by the Master User to arm and disarm any combination, or all 3
partitions, irrespective of the authorization of its corresponding user code.
Here you can add (enroll) the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2) Keyfob transmitters and
define which of the 3 partitions each of the keyfob will be authorized to arm and disarm, or delete keyfobs as
required.
1. Before anything else, gather up all keyfob units you intend to enroll and make sure they all have
batteries installed and that they are active (the LED blinks upon pressing any of the buttons).
2. Carefully read the section titled "Additional Information" according to the indicated references
1
etc –
see table at end of this section.
A. To Add (Enroll) a Keyfob
1.
KEYFOBS
Enter the [USER SETTINGS] menu, select the [KEYFOBS] option and press
.
1
2.
ADD NEW KEYFOB
The display will read [ADD NEW KEYFOB].
4
To enroll a new keyfob press
.
3.
ENROLL NOW or
The display offers you two alternative methods to enroll a keyfob:
ENTR ID:xxx-xxxx
A: ENROLL NOW: Press and hold the AUX button on the selected keyfob
until the LED is constantly on.
2
This procedure completes the enrollment.
4a.
DEVICE ENROLLED
If enrollment was successfully completed, a "Happy Tune"
sounds and
the display reads [DEVICE ENROLLED] for a short duration and then
changes to read the keyfob's details. Continue to step 5.
Go to step 5
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info