D-304829 PowerMaster-10/30 G2 User's Guide 25
B.4 Programming User Codes
PowerMaster system allows you to authorize up to 8 people (PowerMaster-10 G2) / 48 people (PowerMaster-
30 G2) to arm and disarm the system by providing each with a unique 4 digit personal security code, and
assigning them with different security levels and functionalities. Moreover, you can obtain up to 8
(PowerMaster-10 G2) / 32 (PowerMaster-30 G2) multi-function portable keyfob transmitters that will allow you
and the other users to easily arm, disarm and control the system without accessing the panel, including from
outside the premises (see section B.7 Add / Delete Keyfob Transmitters). The Duress Code enables you to
disarm the system using a special code that sends a silent alarm to the monitoring station.
There are two types of users: Master User and User. The table below summarizes the different operations that
can be performed by different users:
User type Function
Master User
Arm/disarm
Zone bypass
Authorize other user codes
Set user codes
Report to private
Enroll/delete proximity tag
Enroll/delete keyfob
Automatic arming
Enable squawk
Set date and time format
Read event log
Programming the duress code
Programming the scheduler
Enabling/disabling voice option
Adjusting volume of system
beeps, chime signal and voice
prompts,
User
Arm/disarm
Zone bypass options
The user codes are assigned as follows:
User Code 1 is assigned to the Master User of the system (i.e. the owner). It is the only user code that allows
access to the User Settings menu. The default setting of the Master User code is 1111. This code cannot be
erased and must be replaced with a secret code as soon as possible.
User Codes 2-4 (PowerMaster-10 G2) / User Codes 2-22 and 33-48 (PowerMaster-30 G2) are assigned to
family members, co-workers etc. They enable arming and disarming of the system or of selected partitions as
defined by the Master User. They can access the "User Settings" menu only for "zone bypassing" provided this
option is enabled in the Installer menu.
User Codes 5-8 (PowerMaster-10 G2) / User Codes 23-32 (PowerMaster-30 G2) are the same as user
codes 2-4 / 2-22 but can be assigned to "Latchkey" (child monitor) users. For a detailed explanation of the
Latchkey application see Chapter 2 (Arming in the Latchkey Mode) and Appendix C.
Partition Option (For information about Partition option - see Appendix B)
Your alarm system can divide zones into up to 3 parts (groups) via the installer menu. These parts are
designated as partitions P1, P2 & P3. Each partition can be armed and disarmed separately providing
protection to selected parts of the premises.
Each user out of the 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2) system users can be authorized by the
Master User to arm and disarm any combination of partitions including all 3 partitions.
Here you can program (or edit) the 8 (PowerMaster-10 G2) /48 (PowerMaster-30 G2) User Codes and
thereby define which of these will be authorized to arm and disarm.
1. The default setting 1111 of the Master User Code is the same for all PowerMaster systems and is
known to many other people. Therefore, we highly recommend that you immediately replace it with a
unique secret code. Never set any user code the same as any installer code.
2. Code "0000" is not valid! Do not use it.
3. The duress code (2580 by default), which is set in the installer menu, cannot be selected as a normal
user code. Any attempt to program it will be rejected by the system.
4. Carefully read the section titled "Additional Information" according to the indicated references
1
etc –
see table at end of this section.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info