622293
7
Zoom out
Zoom in
Previous page
1/50
Next page
DVM601
22/08/2013 ©2008 Velleman
®
Components nv
7
the red lead connection.
Press the Hz/% button to switch to frequency; press again to see the
duty cycle (%).
Range
Range
Resolution
Range
Resolution
400.0mV*
40.00V
10mV
600V
1V
4.000V
400.0V
100mV
*: no auto-ranging for AC
AC/DC current measurement
Connect the red test lead to the µA/mA [6] input jack (max. 400mA) or
10A [7] input jack and the black test lead to the COM jack [5].
Set the rotary switch [3] in the desired current range (<4mA: µA ,
<400mA: mA , <10A: 10A ) and use the mode button [3] to
choose between AC and DC current.
Open the circuit in which the current is to be measured and connect the
test leads to the circuit IN SERIES.
Read the current value and the polarity of the red lead connection on the
LCD display.
Range
Resolution
Range
Resolution
400.0µA
0.1µA
400.0mA
100µA
4000µA
A
10A
10mA
Resistance, diode test and audible continuity test
Connect the red test lead to the Ω-jack [4] and the black test lead to the
COM jack [5] (the red lead has a positive polarity "+").
Set the rotary switch [3] in the range position. Do not apply input
voltage at this setting!
Use the mode button [13] to choose between Ω, diode or continuity test.
If the resistance being measured is connected to a circuit, turn off the
power and discharge all capacitors before applying the test probes.
Connect the test leads to the resistor to be measured and read the LCD
display.
Note: wait a few seconds for a stable reading when measuring resistors >
1MΩ.
Range
Range
Resolution
Range
Resolution
400.0Ω 0.1Ω 40.00 10Ω 4.000 10
4.000
400.0
100Ω
40.00
1MΩ
For diode tests, connect the red test lead to the anode of the diode to be
tested and the black test lead to the cathode of the diode. The approx.
forward voltage drop of the diode will be displayed (typically 0.400
0.700V). If the connection is reversed, the display will show “OL.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM601 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info