622293
5
Zoom out
Zoom in
Previous page
1/50
Next page
DVM601
22/08/2013 ©2008 Velleman
®
Components nv
5
9
light sensor
long life silicon light sensor diode
10
Hz/% button
switch to Hz/% measurement available when measuring AC/DC
voltage, AC/DC current and Hz/%
11
hold/backlight button
Freeze/unfreeze all values on the display. Press and hold for ±3s to
switch backlight on/off.
12
°C/°F mode button
Switch room temperature reading between °C and °F
13
mode button
Switch between AC and DC current measurement; switch between Ω,
diode and continuity test.
14
range button
Select displayed measurement range manually.
15
REL button
Press to store the current measuring result and start measuring against
this value. Press again to exit relative measurement mode.
16
Non-Contact Voltage (NCV) indicator
turns on when the built-in non-contact AC voltage detector detects AC
voltages
6. Use
General
When the range of the measured signal is unknown, start measurement
in auto-range mode, and then select range according to indicated value.
The display shows “OL” when the present range limit is exceeded. Select
a higher range to continue measurement.
Do not measure voltages > 600 V or current higher than 500mA (mA/µA
jack [6]) or 10 A (10A jack [7]). Note that the meter can only handle
10A for less than 30 seconds (with 15 minutes cool-down time).
The device will go in sleep mode when no activity is detected for ±30
minutes. Press any button to re-activate.
Sound level measurement
Set the rotary switch [3] to the dBC-position.
Point the microphone [8] towards the sound source for more accurate
measurement. The sound level will be displayed.
Note: strong wind (over 10m/s) will have a negative impact on the
measurement.
Humidity measurement
Set the rotary switch [3] to any position (except OFF).
The relative humidity at the current location is measured ([1]) and the
value is shown on the top line of the LCD [2]. For more accurate results,
let the multimeter acclimatize for ±2h before measuring.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM601 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info