622293
6
Zoom out
Zoom in
Previous page
1/50
Next page
DVM601
22/08/2013 ©2008 Velleman
®
Components nv
6
Light measurement
Set the rotary switch [3] to the Lux- or Lux 10x-position.
Point the light sensor [9] towards the light source for more accurate
measurement. The light level will be displayed [7].
Note: sensor calibrated to standard incandescent lamp @ 2856K
Room temperature
Set the rotary switch [3] to any position (except OFF).
The room temperature at the current location is measured ([1]) and the
value is shown on the top line of the LCD [2].
Thermocouple temperature
Set the rotary switch [3] in the °C or °F position. Do not apply input
voltage at this setting!
Insert the thermocouple adaptor into the temp input [4] and COM input
[5].
Plug the thermocouple itself into the adaptor (if not done yet). There is
only one way possible, do not force.
Use the other end of the thermocouple to measure temperatures.
Temperature is shown on the LCD [5].
Notes:
do not expose the multi-meter itself to temperatures lower than 0°C
(32°F) or higher than 40°C (104°F).
Do not change the probe, as this will influence measuring accuracy.
AC/DC voltage measurement
Connect the red test lead to the V input jack [4] and the black lead to
the COM input jack [5].
Set the rotary switch [3] in the desired position (V , V , mV ). If
the voltage to be measured is unknown beforehand, set the range switch
in the highest range position and then reduce gradually until the ideal
resolution is obtained.
Use the mode button [13] to choose between AC and DC voltage.
Connect the test leads to the source being measured.
Read the voltage value on the LCD display [2] along with the polarity of
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM601 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info