756404
10
Zoom out
Zoom in
Previous page
1/18
Next page
10 EN
pyrometer controlled via smartphone BP21WP
Performing an individual spot measurement with image
If you have selected individual spot measurement with image,
you will be prompted to choose whether you want to use a
photo already saved in the mobile device's gallery or take a new
one directly in the app. Choose an image section that best
matches the measuring surface.
For measured value data logging please proceed as follows:
1. Tap the screen at the exact measuring location. The
measured value will be displayed at this location.
2. You can also press the On/ off/ measurement button(3)
on the appSensor.
ðThe measured value will be displayed in a specified grid
on the background image. Pressing the Shift measuring
point button(20) allows you to adjust the position of the
measuring points. By pressing the Shift measuring point
button(20) once more you can return to the measuring
mode.
17
9
19
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Measured value for 1.3
Undo
20
BP21WP
Temperature [24,7 | 25,4] Ø 25 25,3 °C
24,7
25,4
24,9
No. Designation Meaning
9 Numeric value
display
Indicates the minimum, maximum and
average values for the temperature as
well as the current temperature value.
17 RECbutton Opens the context menu for sensors.
19 Measuring field
indication
Indicates the image of the measuring
field and the values measured at the
measuring points.
20 Shift measuring
point button
Stops the measured value data
logging and allows you to relocate the
measuring points on the background
image.
Performing a matrix measurement without background
image
In case of a matrix measurement an entire series of measuring
points is captured using a grid the size of which has to be
selected.
1. Always start a matrix measurement in the top left corner
(1st row, 1st column).
ðThe grid field to be measured flashes.
2. Perform the measurement in the flashing grid field.
3. Confirm the measured value by pressing the Measured
value data loggingbutton(22). You can reset a logged
value by pressing UNDO(23). You can skip the indicated
grid field and continue with the measurement in the next
by pressing the SKIPbutton(24).
ðThe displayed measurement grid(21) moves on to the
next line.
4. Perform the next measurement at the given point.
5. Press NEW COLUMN(25) when you have completed the
measurements of all lines in one column so as to move on
to the next.
17
9
21
Sensors MEASUREMEN
TS
Reports CUSTOMERS SETTINGS
Measured value for 1.3
Undo
Skip
New column
22
23
24
25
BP21WP
Temperature[24,7 | 25,4] Ø 25 25,3 °C
No. Designation Meaning
9 Numeric value
display
Indicates the minimum, maximum and
average values for the temperature as
well as the current temperature value.
17 RECbutton Opens the context menu for sensors.
21 Measuring field
with grid
Indicates the measurement grid of the
measuring field (grid field to be
measured flashes red).
22 Measured value
data logging button
Saves the measured value for the
flashing grid field.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec BP21WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec BP21WP in the language / languages: English as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec BP21WP

Trotec BP21WP User Manual - German - 18 pages

Trotec BP21WP User Manual - Dutch - 17 pages

Trotec BP21WP User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info