756404
16
Zoom out
Zoom in
Previous page
1/18
Next page
16 EN
pyrometer controlled via smartphone BP21WP
Disconnecting an appSensor
Proceed as follows to disconnect an appSensor from the
terminal device:
1. Press the SENSORS button(6).
ðA list of connected and available sensors will be
displayed.
2. Select the line with the appSensor to be disconnected and
swipe left at the red marking.
3. Confirm your input.
ðThe appSensor is now disconnected from the terminal
device and can be switched off.
4. Alternatively, you can press the Menubutton(11).
ðThe context menu opens.
5. Press the Disconnect sensor button(14).
6. Confirm your input.
ðThe appSensor is now disconnected from the terminal
device and can be switched off.
Switching off an appSensor
Info
Always terminate the connection between appSensor
and app before you switch off the appSensor.
Proceed as follows to switch off an appSensor:
1. Press and hold the On/ off/ measurement button(3) for
approx. 3seconds.
ðThe LED(2) on the appSensor goes out.
ðThe appSensor is switched off.
2. You may now exit the Trotec MultiMeasure Mobile app on
the terminal device.
Maintenance and repair
Battery change
A battery change is required when the LED at the device flashes
red or the device can no longer be switched on. See chapter
Operation.
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Bluetooth connection is terminated or interrupted
Check whether the LED at the appSensor flashes green.
If so, briefly switch it off completely, then turn it back on.
Establish a new connection to the terminal device.
Check the battery voltage and insert new or freshly
charged batteries, if required.
Does the distance between appSensor and terminal device
exceed the appSensor's radio range (see chapter Technical
data) or are there any solid building parts (walls, pillars
etc.) situated between appSensor and terminal device?
Shorten the distance between the two devices and ensure
a direct line of sight.
The sensor cannot be connected to the terminal device
although it is displayed there.
Check the Bluetooth settings of your terminal device.
A possible reason for this could be special, manufacturer-
specific settings relating to an improved location accuracy.
Enable these settings, then try to establish a connection to
the sensor again.
Further information and assistance regarding the used sensor
type will be provided in the MultiMeasure Mobile app via the
menu item Settings=> Help. Selecting the menu item Help
opens a link to the app's help page. You can open a drop-down
menu with numerous support entries from the Table of
contents. Optionally, you can also scroll through the entire help
page and thoroughly acquaint yourself with the individual help
topics.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec BP21WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec BP21WP in the language / languages: English as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec BP21WP

Trotec BP21WP User Manual - German - 18 pages

Trotec BP21WP User Manual - Dutch - 17 pages

Trotec BP21WP User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info