782362
23
Zoom out
Zoom in
Previous page
1/296
Next page
23GB
2 Maintenance and repair
Pull out the mains plug for any adjustment or re-
pair tasks.
The generation of noise is inuenced by various
factors, including the characteristics of saw blades,
condition of saw blade and electric tool. Use saw
blades which were designed for reduced noise
development, insofar as possible. Maintain the
electric tool and tool attachments regularly and if
necessary, initiate repairs in order to reduce noise.
Report faults on the electric tool, protective devices
or the tool attachment to the person responsible for
safety as soon as they are discovered.
3 Safe work
Only use saw blades for which the maximum per-
missible speed is not lower than the maximum
spindle speed of table saws and which are suit-
able for the material to be cut.
Make sure that the saw blade does not touch the
rotary table in any position by pulling out the mains
plug and rotating the saw blade by hand in the
45° and 90° position. If necessary, readjust the
saw head.
When transporting the electric tool, only use the
transport devices. Never use the protective devices
for handling or transport.
Make sure that the lower part of the saw blade is
covered during transport, e.g. by the protective
device.
Be sure to only use spacers and spindle rings
specied by the manufacturer as suitable for the
intended purpose.
The oor around the machine must be level, clean
and free of loose particles, such as chips and cut-
ting residues.
Do not remove any cutting residues or other parts
of workpieces from the cutting zone while the ma-
chine is running and the saw unit is not at rest.
Make sure that the machine is always secured on
a workbench or a table if at all possible.
Support long workpieces (e.g. with a roller table) to
prevent them sagging at the end of a cut.
Warning! This electric tool generates an electromag-
netic eld during operation. This eld can impair active
or passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.
SAFETY INSTRUCTIONS FOR THE HANDLING OF
SAW BLADES
1 Only use insertion tools if you have mastered their
use.
2 Observe the maximum speed. The maximum speed
specied on the insertion tool may not be exceeded.
If specied, observe the speed range.
3 Observe the motor / saw blade direction of rotation.
4 Do not use any insertion tools with cracks. Sort out
cracked insertion tools. Repairs are not permitted.
5 Clean grease, oil and water off of the clamping sur-
faces.
6 Do not use any loose reducing rings or bushes for
the reducing of holes on saw blades.
7 Make sure that xed reducer rings for securing the
insertion tool have the same diameter and have at
least 1/3 of the cutting diameter.
8 Make sure that xed reducer rings are parallel to
each other.
9 Handle insertion tool with caution. They are ideally
stored in the originally package or special containers.
Wear protective gloves in order to improve grip and
to further reduce the risk of injury.
10 Prior to the use of insertion tools, make sure that all
protective devices are properly fastened.
11 Prior to use, make sure that the insertion tool meets
the technical requirements of this electric tool and is
properly fastened.
12 Only use the supplied saw blade for sawing opera-
tions in wood, materials similar to wood, plastics and
non-ferrous metals (except for magnesium and alloys
containing magnesium).
Attention: Laser radiation
Do not stare into the beam
Class 2 laser
Protect yourself and you environment from acci-
dents using suitable precautionary measures!
Do not look directly into the laser beam with unpro-
tected eyes.
Never look into the path of the beam.
Never point the laser beam towards reecting surfaces
and persons or animals. Even a laser beam with a low
output can cause damage to the eyes.
Caution - methods other than those specied here can
result in dangerous radiation exposure.
Never open the laser module. Unexpected exposure
to the beam can occur.
If the mitre saw is not used for an extended period of
time, the batteries should be removed.
The laser may not be replaced with a different type
of laser.
Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representative.
Safety instructions for handling batteries
1 Always make sure that the batteries are inserted
with the correct polarity (+ and –), as indicated on
the battery.
2 Do not short-circuit batteries.
3 Do not charge non-rechargeable batteries.
4 Do not overcharge batteries!
5 Do not mix old and new batteries or batteries of
different types or manufacturers! Replace an entire
set of batteries at the same time.
6 Immediately remove used batteries from the device
and dispose of them properly!
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toolson KGZ2550PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toolson KGZ2550PRO in the language / languages: All languages as an attachment in your email.

The manual is 13.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info