If the appliance again switches off due to the intervention of the outlet safety, you should have the outlet sys-
tem (chimney) inspected by a registered installer. This safety device must not be rendered inoperative or al-
tered, because the system will not function properly otherwise. Only original ThermoCet components must
be used for replacement. This also applies to the fastening materials and wiring.
Possible causes of the intervention of the outlet safety are:
* A poor connection between the fire and the chimney.
* The chimney is completely or partially blocked by fallen debris etc.
* The draught is inadequate.
* Negative pressure in the room as a result of an extractor hood or central extraction system which is too
strong.
Consult your installer if this situation arises!
4. ELECTRICAL INSTALLATION INSTRUCTIONS ( only for Versa HV )
The appliance is fitted with a fan and must be connected to an earthed 230VAC/50Hz wall socket. Installa-
tion must be in accordance with NEN 1010 and local regulations. Always ensure that the wall socket is still
easily accessible after the appliance has been installed.
Technical specifications fan: 230V, 50Hz Power 25 w
Only original ThermoCet components must be used for replacement.
5. GAS INSTALLATION INSTRUCTIONS
5.1 General instructions
* The appliance should only be installed and connected by a registered installer in accordance with the
local Gas Appliance Regulations.
* The Versa HV is fitted with a fan and must be connected to a 230VAC/50 Hz alternating current
earthed wall socket, in compliance with NEN 1010 and local regulations. If necessary, place the wall
socket on the right-hand side of the fire, where a special opening has been made for a gas pipe and a
connecting lead and plug. Never shorten the connection lead, since this would complicate the removal
of the burner unit. Never position the fireplace against or in a combustible wall.
* If the fireplace is being connected to a chimney which has previously been fired with wood, coal or
oil, the chimney must be thoroughly inspected and cleaned. A draught of approximately 0.5 mm water
column is sufficient, measured when the fire is at full power.
If the draught is in excess of 2 mm water column, it is advisable to reduce the draught. If the room is fitted
with a window fan, or if the fireplace is being installed in a chink-free dwelling, pressure equalization open-
ings must be made into the outside air. This must be done to prevent the chimney from not working as a re-
sult of any negative pressure.
When gas fires are being installed, we recommend that these are connected to a fully aluminium or stainless
steel outlet duct measuring 100 mm, in order to avoid problems with the thermal outlet safety and other fea-
tures. If the appliance is being connected to an existing duct which had previously been fired with wood, coal
or oil, we also recommend that the above-mentioned aluminium or stainless steel flue be fitted.
5.2 Preparations for installing the fireplace
In order to build-in the fireplace, it must first be dismantled as described below.
1. Remove the front from the fireplace once it has been taken out of the box. To do this, loosen the
fastening screws: 2 inside the front at the top and 2 inside the front at the bottom, behind the service
door.
5


Need help? Post your question in this forum.

Forumrules
1

Forum

thermocet-versa-lv-hv

Reset search

  • Hi my versa lv fire would not stay lit, we have cleaned it and now it lights but only stays lit for about 30 seconds and goes out again. Does anyone have any advice? Submitted on 19-3-2022 at 12:34

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet VERSA LV-HV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet VERSA LV-HV in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info