607255
11
Zoom out
Zoom in
Previous page
1/30
Next page
Page.11
8. Additional instructions for the Mertik Maxitrol GV60 and the remote control.
Ensure that the fuel supplied to the unit is clean and free from particles and moisture.
Before a gas supply pipe (new or existing) is connected to the main gas pipe at the gas meter and to the gascon-
trol block of the unit, clean and dry compressed air should be blown through it. Cut copper pipes as well as alu-
minium pilot pipes (diameter = 4 mm) must be deburred and blown clean before they are connected.
The dust filter at the connection to the gas control block will only filter out the coarsest dirt from the system.
Fine particles are still able to reach the inside and may damage and/or adversely affect regulation in the gas con-
trol block.
Heat, moisture and dust are a threat to all electronic components
Install the electronic gas control only after all construction, plastering and paintwork has been completed. If
work such as this is unavoidably still being carried out, then protect the control box against dirt and moisture
penetration by using, for example, plastic film.
Do not extend the thermocouple supplied to the pilot set
Extending the thermocouple beyond this limit will lead to a reduction in voltage. This may, in turn, lead to the
magnetic coil not being activated.
Prevent leakage of the ignition spark to parts of the installation other than the ignition rod at the pilot.
Ensure the ignition cable is not in contact with the shell or other metal parts. If a cable extension is used, ensure
that connections are additionally insulated using silicone
The receiver and the control units on the gas control block should be switched on to ensure automatic
start-up through the manual transmitter.
The oval disk on the gas control block should be turned to the ON position. The 1/0 switch should be set to 1.
See photograph 2. The ignition cable should be connected to the SPARK connection point on the receiver box.
See photograph 1.
The manual transmitter has to communicate with the receiver. This has to be ‘learnt’.
Press the RESET button using a blunt object. (See photograph 3.) Continue to press this button until you hear a
short beeping sound, followed immediately afterwards by a long beeping signal. Release the button.
Direct the handset towards the receiver and press the arrow down until you hear a long beeping sound. The gas
control button will now move for a short period. The hand transmitter has now learned the setting with regard to
the receiver and the unit can now be ignited by using the remote control.
The system’s thermostat sensor is in the manual transmitter.
The manual transmitter operates best at a distance of 2 or 3 metres from the unit. Although communication oc-
curs via short wave radio signals, it is recommended to place the hand transmitter in view of the gas apparatus in
a place where the user wishes to experience a pleasant temperature. Do not place the hand transmitter in direct
sun light or at another warm location. The thermostat measures the temperature and regulates the flame level of
the gas unit accordingly.
Only remove batteries using non-metallic tools.
Removing batteries with a metal object may damage the electronic control permanently.
Photo 3
Photo 1
40 mm
Photo 2
A2
A4
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Flat Fire M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Flat Fire M in the language / languages: English as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info