607255
10
Zoom out
Zoom in
Previous page
1/30
Next page
Page.10
6. Gas specifications
AT I2H, I3B/P BE I2E+ , I3+ DK I2H, I3B/P DE I2ELL, I3B/P
FI I2H, I3B/P FR I2E+, I3+ GR I2H, I3B/P GB I2H, I3+
IS I3B/P IE I2H, I3+ IT I2H, I3+ LU I2E, I3B/P
NL I2L, I3B/P NO I3B/P PT I2H, I3+ ES I2H, I3+
SE I2H, I3B/P CY I3B/P,I3+ EE I3B/P,I2H LT I3B/P,I2H
LV I3B/P,I2H MT I3B/P, HU I3B/P,I2H PL I3B/P
SI I3B/P,I2H SK I2H
7. Technical specifications (see also Page 16)
Model : Flat Fire M
Gas block type : Mertik GV60
Ignition : Distance operation and Piezo ignition
Gas connection : 3/8 “ (Internal)
Unit category : C11-C31
Pilot : SIT 3 Flams
Combustion gas discharge
and Combustion air supply : Concentric: Ø 100/150 mm
Radio controlled Transfer Frequency:
ON 40.5 kHz, OFF 40 kHz
Range: 0.5…10m
Ambient temperature:
Transmitter and receiver: max. 60ºC
Connection cables: max. 180ºC
CATEGORIE I2L I2H I2E+ I2E+ 12E I2ELL
COUNTRY NL SP FR BE DE DE
PRIMARY AIRINLET 2 X Ø6,5MM 2 X Ø4,6MM 2 X Ø4,6MM 2 X Ø4,6MM 2 X Ø4,6MM 2 X Ø4,6MM
PREPRESSURE MBAR 25 20 20 20 20 20
BURNER PRESSURE MBAR 22,2 15,4 15,4 15,4 15,4 19,5
BURNER INJECTOR MM
2,1 2,1 2,1 2,1 2,1 2,1
PILOTBURNER INJECTOR CODE 41 41 41 41 41 41
NOM. LOAD (PCI) KW 6,43 6,37 6,37 6,37 6,37 6,37
GAS CONSUMPTION HI M³/h 0,798 0,670 0,67 0,67 0,67
GAS CONSUMPTION LOW M³/h
0,440 0,323 0,323 0,323 0,323
NOM. CAPASITY Kw
5,34 5,36 5,36 5,36 5,36 4
CATEGORIE I3P I3+ I3B/P I3B/P I3B/P
G31 G30 G30/G31 G30/G31 G30/G31 G30/G31
COUNTRY NL/NO FR/SP BE DE GB
PRIMARY AIRINLET OPEN OPEN OPEN OPEN OPEN OPEN
PREPRESSURE MBAR
37 30 37/30 37/30 50/50 37/30
BURNERPRESSURE MBAR 29,2 28,2 29,2 29,2 29,2 29,2
BURNER INJECTION MM 1,2 1,2 1,2 1,2 1,2 1,2
PILOTBURNER INJECTOR CODE 30 30 30 30 30 30
NOM. LOAD (PCI) KW
5,29 6 5,29 5,29 5,29 5,29
GAS CONSUMPTION HI M³/h 0,22 0,19 0,22 0,22 0,22 0,22
GAS CONSUMPTION LOW M³/h 0,087 0,076 0,087 0,087 0,087 0,087
NOM. CAPASITY kw 4,18 4,92 4,18 4,18 4,18 4,18
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Flat Fire M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Flat Fire M in the language / languages: English as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info