In order for the electrical circuit
breaker devices to operate correctly, the gen-
erator is supplied with an output voltage at
230 V ~ related to its mechanical and electri-
cal mass. Should technical considerations
require a different configuration, remove the
yellow-green jumper linking the GND and N
terminals.
The generator has an internal protection against
overloads. It is preferable, however, to install a
thermomagnetic cutout switch for single-phase
network in the utility distribution control panel
with maximum capacity 12 A. It is advisable to
close the switch after starting the generator and
reopen it before stopping it
5.5 Cut-off Relay connection
If a 230 V~ voltage is applied to the
generating set output, even for a short time,
the equipment may suffer serious damage.
On the distribution system of the 230 V~ power
line, immediately downstream from the generator
as indicated in fig.19, a cut-off relay (for example,
code 05423, optional) or another automatic
switch should be installed to isolate the generator
when the system is supplied 230 V~ mains
voltage.
Connect the relay (fig.19 ref. 1) as follows:
Connect the two wires of the 230 V output line
of the generating set (fig.19 ref. 2) to the PINS
1 - 3.
Connect the two wires of the direct line to the
utilities to the PINS 7 - 9.
Connect the two wires of the 230 V external
line (fig.19 ref.5) to the PINS 6 - 4.
Jumper the PINS 4 – A.
Jumper the PINS 6 – B.
Fig.19 also shows the connection of a thermo-
magnetic + safety cutout switch (fig.19 ref. 3), not
supplied with the generator.
5.6 Electronic control panel connection
Choose your required position for the control
panel inside the vehicle and drill a 35 x 25 mm
rectangular hole (fig.20 ref.1) on the wall to re-
ceive the panel connectors.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair TIG3000B Inverter generator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair TIG3000B Inverter generator in the language / languages: English as an attachment in your email.

The manual is 12,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Telair TIG3000B Inverter generator

Telair TIG3000B Inverter generator User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info