688826
13
Zoom out
Zoom in
Previous page
1/44
Next page
Vers. 001
TIG 3000 B
13
GB
auxiliary services wires must be connected to the
terminal strip (fig.16 ref.4), the control panel and
the other electrical controls to the connectors
(fig.16 ref.5).
5.3 Battery connection
On the positive power supply line con-
nected to the generator, next to the battery,
provide a 60 A rating fuse.
The connection to a battery with volt-
age different from 12 volts or the reversal of
polarity will cause irreversible damage to the
generator.
The generator must be connected to a 12 Volt
battery (for the required specifications see the
table with generator data). Depending on the re-
quirements it can be connected either to the ve-
hicle battery or to the service battery.
The connected battery is charged by the genera-
tor itself with a maximum current of about 10 A.
For connection purposes, insulated cables of dif-
ferent colours should be used (usually red and
black, connected to the positive pole and nega-
tive pole - respectively) with sections:
10 mm² for lengths up to 6 metres
16 mm² for longer lengths.
On the generator side, each wire should be fixed
to an eyelet terminal with a Ø 6 mm hole. By ob-
serving polarity indications, fix the eyelets to the
studs + and - on the generator (fig.17 ref. 1,
fig.17 ref. 2) taking care to use two wrenches as
shown in fig.17, to stop the studs from turning.
5.4 Connection to a 230 V~ utility
Incorrect connections or connections
performed with wires not up to 230 V~ voltage
requirements can damage the generator and
its connected utilities as well as endanger
users.
The generator has a terminal strip for connection
to 230 V~ utilities (fig. 18 ref. 1) and another for
optional service connections (fig. 18 ref. 2).
Connection of 230 V~ utilities should be carried
out by using insulated leads with a 2.5 mm² sec-
tion, in compliance with the regulations in force.
The output terminals are marked with Ph
(Phase), N (Neutral) and GND (metal Ground).
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair TIG3000B Inverter generator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair TIG3000B Inverter generator in the language / languages: English as an attachment in your email.

The manual is 12,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Telair TIG3000B Inverter generator

Telair TIG3000B Inverter generator User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info