688848
11
Zoom out
Zoom in
Previous page
1/44
Next page
Vers. 002
Energy 2510 D
GB
11
4.6 Auxiliary battery charger connection
It is possible to connect a battery other than the
one connected to the generator through the 2-pin
connector (fig. 15 ref. 3), on which there is an
alternated voltage of 12 V 50 Hz, max current 5
A; this can be done by installing a charge
regulator RCB (optional, item code 05424)
between this connector and the battery.
Do not directly connect
any battery to this connector!
5 Electric connections
5.1 Preparing the Wiring connection
By using the special key to open the lock,
remove the front door (fig. 16 ref. 3).
Then remove the bottom surface locking screw
(fig. 16 ref. 1) on both sides.
Take out the bottom surface with the engine all
the way to the mechanical stop (fig. 17).
If you wish to completely remove the engine
surface, screw out the setscrews (fig. 16 ref. 2)
too.
5.2 230 VAC wiring connection
To connect loads to the power generating set,
use a three-pole cable up to the applicable
standards in force. The correct cross section is
shown in
Table 1.
For connection to the 230V input line, the
generating set is equipped with a special terminal
strip (fig. 18 ref. 2) to which the cables must be
connected.
Make sure the rubber fairlead is well positioned
to prevent water seepage
Even if the generating set is provided with a
thermoswitch to disconnect power supply (fig. 18
ref. 1) in case of overload or short-circuit, a
suitably calibrated circuit breaker should be
installed inside the switchboard of the vehicle,
which disconnects the power line to users
whenever power input exceeds
9,5 A.
If the thermoswith of the generating set has been
operated, press the button (fig. 18 ref. 1) to
restore closed circuit and power delivery
conditions.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510D in the language / languages: English as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info