688848
12
Zoom out
Zoom in
Previous page
1/44
Next page
Energy 2510 D
Vers. 002
12
GB
5.3 Connecting an External Network Relay
An (optional) relay or change-over switch code
05423) (fig. 19) should be fitted to the vehicle
wiring system. Its purpose is to insulate the
generating set when it is connected to an
external electric input network.
Connect the relay according to the following
instructions:
Connect the two wires of the 230 V line of the
generating set to the PINS 1 - 3.
Connect the user line to the PINS 7 - 9.
Connect the external line to the PINS 6 – 4.
Jumper the PINS 4 – A.
Jumper the PINS 6 – B.
Check the proper
position of the 230 V current pick-up line
carefully. A wrong connection could cause
irreparable damage to the generating set or
create dangerous short circuits.
Table 1
LINE CONNECTION 230 Vac
Length < 6 m Length > 6 m
Cross Section 2.5 mm
2
Cross Section 4 mm
2
BATTERY CONNECTION
Length < 6 m Length > 6 m
Cross Section 25 mm
2
Cross Section 36 mm
2
Electric connections to
the generating set should be carried out by
skilled personnel only.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510D in the language / languages: English as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info