617906
86
Zoom out
Zoom in
Previous page
1/128
Next page
86
TASCAM HS-20
10 – Internal settings
RS–422 page
Make RS-422 serial control transmission settings on this page.
NOTE
If an optional SY-2 has not been installed, the items will be
shaded and cannot be set.
Serial Mode
Set the serial connection mode with the following buttons.
Setting buttons: RS-232C (Default), RS-422
NOTE
Only the connector selected with this setting will function.
The RS-232C and RS-422 connectors cannot both be used
at the same time.
This setting is synchronized with the Serial Mode item on the
RS-232C page.
If an optional SY-2 has not been installed, this cannot be set
to RS-422.
Video Resolve
When slaving this unit to a VCR, video sync signals might be
used instead of word sync signals for the common standard
clock. In the same way as with word sync signals, you can
select whether the video clock is followed (synchronizing
the beginning of timecode frames with video signal frame
edges) or it is independent from the frame clock.
This must be turned ON to accurately control this unit from
a video editor.
ON (default): timecode frame edges synchronized with
video signal frame edges
OFF: Independent from video frame clock
NETWORK page
Make settings related to NETWORK communication on this
page.
STATUS
Shows the MAC Address of this unit and the current IP
Address.
Password
Press the Change button to open the CHANGE PASSWORD
screen.
IP MODE
Use these buttons to enable or disable network functions.
Setting buttons: Disable (default), Enable
IP SETUP
Use this section to set the IP Address, Subnet Mask and
Default Gateway.
AUTO: The IP Address, Subnet Mask and Default
Gateway are set automatically.
Use this setting when a DHCP server exists
on the network.
STATIC:
(default value)
Set the IP Address, Subnet Mask and Default
Gateway manually.
IP Address/Subnet Mask/Default Gateway
When IP SETUP is set to STATIC, the IP Address, Subnet Mask
and Default Gateway are shown here.
Touch an area to open a corresponding setting screen.
Default: 0. 0. 0. 0.
Depending on the IP SETUP setting, the appearance of this
area will change as follows:
When touching
When setting STATIC
When setting AUTO
DNS SETUP
Set the DNS server IP address so that the IP address can be
looked up by server name.
AUTO: The DNS server IP Address is set automati-
cally.
Use this setting when a DHCP server that
can return a DNS server IP address exists on
the network.
STATIC:
(default value)
Set the DNS server IP Address manually.
DNS Address
When DNS setup is set to STATIC, this shows the DNS server
IP address. Touch it to open a setting screen.
Default: 0. 0. 0. 0.
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tascam HS-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tascam HS-20 in the language / languages: English as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info